Processor
Number 1 or 2 Processors
CPUs Intel Xeon Platinum 8160: 2.1GHz, 24-core, 150 watts, XCC, 33MB L3 cache
Intel Xeon Gold 6140: 2.3GHz, 18-core, 140 watts, XCC, 24.75MB L3 cache
Intel Xeon Silver 4114: 2.2GHz, 10-core, 85 watts, LCC 13.75MB L3 cache
Intel Xeon Gold 6128 : 3.4GHz, 6-core, 115 watts, XCC, 19.25MB L3 cache
Main Memory
Capacities
  • 24 DIMM Slots
  • RDIMM Size and Type: 16GB: DDR4-2666 Registered DIMMs, 32GB: DDR4-2666 Registered DIMMs
  • LRDIMM Size and Type: 64GB: DDR4-2666 Load Reduced DIMMs
  • Minimum Memory Capacity: 1 DIMM per installed CPU is the minimum requirement.
  • Maximum Memory Capacity: 1.5TB using 64GB DIMMs in a 2 CPU configuration
Standard I/O
Network Two 10GbE RJ45 Ports or Two 10/25GbE SFP28 Ports
Network Management One 10/100/1000 M Base-T Network Management (NET MGT/RJ-45 connector) port
Serial Management One serial console (SER MGT/RJ-45 connector) port.
USB Rear: 1 USB 3.0 Ports
Internal: 1 USB 3.0 Ports
I/O Expansion Four PCIe 3.0 slots: three external and one internal. The internal slot supports a required internal SAS controller HBA card. PCIe slot 1 is nonfunctional in single-processor systems.
  • PCI-E slot 1: x16 mechanical/x16 electrical
  • PCI-E slot 2: x16 mechanical/x16 electrical
  • PCI-E slot 3 and 4: x8 mechanical/x8 electrical
Internal Mass Storage
Disks Eight front-accessible and hot-swappable 2.5" disk bays.
Up to 8 SAS3 HDDs/SSDs, or up to 8 NVMe SSDs, 2 internal SATA M.2 flash SSDs.

Drive Type
Density
Speed
Form Factor
SAS-3
600GB
10,000 RPM

2.5"
SAS-3
1.2TB
10,000 RPM

2.5"
SAS-3
800GB
Solid State

2.5"
M.2 SATA-3
480GB
Solid State

22mm x 80mm
NVMe
6.4TB
Solid State

2.5"

Power Supplies and Fans
  • Two 1200W hot-swappable and redundant power supplies and 4 hot-swappable and Redundant Fan Modules each with 2 fans.
  • Cooling is front to back.
Environment
Power Consumption Online power calculator
Voltage (nominal) 10A/7A, 100-127/200-240V~, 10/7A, 50/60Hz
Input Current (maximum) 7.2A @ 100-127VAC; 3.4A @ 200-240 VAC
Frequency (nominal) 50/60Hz (47 to 63 Hz range)
Temperature Operating: 5° C to 35° C (41° F to 95° F), Optimal 21° C to 33° C (69.8° F to 73.4° F)
Nonoperating: -40° C to 68° C (-40° F to 154°F)
Note: Maximum ambient operating temperature is derated by 1 degree C per 300 meters of elevation beyond 900 meters, up to a maximum altitude of 3000 meters.
Humidity Operating: 10% to 90% noncondensing short term -5° C to 55° C (23° F to 113° F)
5% to 90% noncondensing, but not to exceed 0.024 kg of water per kg of dry air (0.053 lbs water/2.205 lbs dry air)
Nonoperating: Up to 93% noncondensing 35° C (95° F) maximum wet bulb
Altitude Operating: Up to 3,000 m (9,840 ft.)
Note: In China markets, regulations may limit installations to a maximum altitude of 2000 meters (6562 ft).
Nonoperating: Up to 12,000 m (39,370 ft.)
Acoustic Noise Emissions 7.1 Bels A-weighted operating, 7.0 Bels A-weighted idling
Vibration Operating: 0.15 G (z-axis); 0.10 G (X-, y-axes), 5-500Hz swept sine; IEC 60068-2-6 Test FC
Nonoperating: 0.5 G (z-axis); 0.25 G (x-, y-axes), 5-500Hz swept sine; IEC 60068-2-6 Test FC
Shock Operating: 3.5 G, 11 ms half-sine; IEC 60068-2-27 Test Ea
Nonoperating:
  • Roll-off: 1.25-inch roll-off free fall, front to back rolling directions
  • Threshold: 13-mm threshold height at 0.65 m/s impact velocity
  • ETE-1010-02 Rev A
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences.
EMC Emissions: FCC 47 CFR 15, ICES-003, EN55022, EN55032, KN32, EN61000-3-2 and EN61000-3-3.
Immunity EN 55024, KN35
Certifications
  • North America Safety (NRTL)
  • European Union (EU)
  • International CB Scheme
  • BIS (India)
  • BSMI (Taiwan)
  • RCM (Australia)
  • CCC (PRC)
  • MSIP (Korea)
  • VCCI (Japan)
  • Morocco
  • Republic of Srpska
European Union Directives
  • 2014/35/EU Low Voltage Directive
  • 2014/30/EU EMC Directive
  • 2011/65/EU RoHS Directive
  • 2012/19/EU WEEE Directive
Dimensions and Weight
Height 42.6 mm (1.7 in.) 1U
Width 482 mm (18.9 in.)
Depth 737 mm (29.0 in.)
Weight Maximum: 18.1 kg (40 lbs.) fully populated.
Rack Mounting
Included Oracle Server X7-2 Rack Mount Kit
  • Tool-less rack mounting slide rail kit
  • Cable management arm
  • Mounting brackets
  • Screws
  • Rack mounting template
Service Clearance Rear: 91.4 cm (36 in.)
Front: 123.2 cm (48.5 in.)

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback