Processor
Number 1 or 2 Processors
Architecture Type: Intel Xeon E5-2600 v4 Processor Series
CPUs 10-Core 2.2GHz Intel E5-2630 v4,   85W
22-Core 2.2GHz Intel E5-2699 v4, 145W
14-Core 2.6GHz Intel E5-2690 v4, 135W
  6-Core 3.4GHz Intel E5-2643 v4, 135W
Cache Level 1: 32 KB instruction and 32 KB data L1 cache per core
Level 2: 256 KB shared data and instruction L2 cache per core
Level 3: Up to 45 MB shared inclusive L3 cache per processor
Main Memory
Capacities
  • 24 DIMM Slots
  • DIMM Size and Type: 16GB: DDR4-2400 Registered DIMMs, 32GB: DDR4-2400 Registered DIMMs, or 64GB: DDR4-2400 Load Reduced DIMMs
  • Minimum Memory Capacity: 1 DIMM per installed CPU is the minimum requirement.
  • Maximum Memory Capacity: 1.5TB using 64GB DIMMs x 24 Slots in a 2 CPU configuration
Standard I/O
Network
  • Four onboard auto-sensing 100/1000/10,000BASE-T gigabit Ethernet (GbE) ports (RJ-45 connector).
    Ethernet ports NET 2 and NET 3 are nonfunctional in single-processor systems.
Network Management One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port.
Serial Management One serial console (SER MGT/RJ-45 connector) port
USB Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports
Graphics
  • One VGA 2D embedded graphics controller with DB-15 connector
  • Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
I/O Expansion Six PCIe 3.0 slots:
  • PCI-E slot 1: x8
  • PCI-E slot 2: x8
  • PCI-E slot 3: x16
  • PCI-E slot 4: x16
  • PCI-E slot 5: x8
  • PCI-E slot 6: x8
Note: PCIe slots 1, 2, and 3 are nonfunctional in single-processor systems.
Internal Mass Storage
Disks, Flash and DVD Three Disk Backplanes configurations
  • Eight-disk chassis: eight SAS-3, 2.5-inch front hot-swappable disk bays and optional DVD-RW drive
  • Twelve-disk chassis: twelve SAS-3, 3.5-inch front hot-swappable disk bays and an additional two 2.5-inch rear hot-swappable disk bays
  • Twenty-four-disk chassis: twenty-four SAS-3, 2.5-inch front hot-swappable disk bays and an additional two 2.5-inch rear hot-swappable disk bays
  • Up to four NVM Express (NVMe) drives (12.8 TB total capacity) are available in eight-disk and twenty-four-disk chassis and up to nine (max of 28.8 TB) in the all-flash confiuration
  • Internal 8GB USB 2.0 Flash Drive
  • The 2.5-inch disk bays can be populated with either HDDs, SSDs, or NVMe
  • The 3.5-inch disk bays can be populated only with HDDs
  • 12 Gbps RAID HBA supporting levels: 0, 1, 5, 6, 10, 50, 60 with 1 GB of DDR3 onboard memory with flash memory backup via embedded internal SAS3 HBA PCIe Card
Power Supplies
  • Two hot-swappable and redundant power supplies, rated 91% efficiency.
Environment
Power Consumption Online power calculator
AC power Rated line voltage: 100 to 240 VAC
Rated input current 100 to 127 VAC 8.5 A and 200 to 240 VAC 5.7 A
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°F)
Humidity Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: Up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3,000 m (9,840 ft) maximum ambient temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft)
Nonoperating: Up to 12,000 m (39,370 ft)
Acoustic Noise Emissions 8.1 Bels A-weighted operating, 5.8 Bels A-weighted idling
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences
EMC Emissions: FCC CFR 47 Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3
Immunity EM55024
Other Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
Certifications
  • North America Safety (NRTL)
  • European Union (EU)
  • International CB Scheme
  • BIS (India)
  • BSMI (Taiwan)
  • RCM (Australia)
  • CCC (PRC)
  • MSIP (Korea)
  • VCCI (Japan)
European Union Directives
    2006/95/EC Low Voltage Directive
  • 2004/108/EC EMC Directive
  • 2011/65/EU RoHS Directive
  • 2012/19/EU WEEE Directive
Dimensions and Weight
Height 87.6 mm (3.5 in.).
Width 445.5 mm (17.5 in.).
Depth 737 mm (29.0 in.).
Weight 8-disk configuration maximum: 24.5 kg (54 lbs.) fully populated
12-disk configuration maximum: 29.9 kg (66 lbs.) fully populated
24-disk configuration maximum: 29.0 kg (64 lbs.) fully populated
Rack Mounting
Oracle Server X6-2L Rack Installation Kits
  • Tooless rackmounting slide rail kit
  • Cable management arm

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.