Processor |
Number |
4 or 8 CMODs (Compute Modules), providing 4 or 8 CPU configurations |
Architecture |
Type: Intel Xeon E7-8895 Processor Series |
CPUs |
Intel 2.6GHz 18-Core Xeon E7-8895 v3, 175W
|
Main
Memory |
Capacities |
- DIMM Slots per CMOD: 24
- Total DIMM Slots: 192
- DIMM Size and Type: 16GB: DDR3L-1600 ECC registered or 32GB:
DDR3L-1600 load-reduced ECC DIMMs (LRDIMM)
- Minimum Populated DIMM Slots per CMOD : 4 DIMMs per CMOD
- Minimum Memory Capacity: 256GB using 16GB DIMMs
- Maximum Memory Capacity: 6TB using 32GB DIMMs
- Memory capacity needs to be equal across all CMODs
- Memory mixing is not allowed
|
Standard
I/O |
Network |
Two 1 GbE network ports (RJ-45 connector) |
Network Management |
One 10/100/1000Base-T Ethernet Service Processor (SP) (RJ-45 connector)
port |
Serial Management |
One RS-232 RJ45 serial console port |
USB |
Rear: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports |
Video |
One VGA 1,280 x1,024x8 MB @ 60 Hz graphics controller port with DB-15
connector |
I/O Expansion |
2 PCI Express 3.0 Slots per CMOD for maximum of 16 Slots. Hot swappable
via Dual PCIe Card Carrier (DPCC).
- 1 x8 PCI-E slot and 1 x16 PCI-E slot per DPCC
- Four CMOD systems support PCIe slots 1 through 8. Install order =
8, 6, 4, 2, 7, 5, 3, 1
- Eight CMOD systems support all 16 PCIe slots. Install order = 12,
10, 8, 6, 4, 2, 11, 9, 7, 5, 3, 1, 16, 14, 15, 13
- PCIe slots 13, 14, 15, and 16 cannot contain bootable devices such
as HBAs or network boot devices
- No mixing of Emulex and Qlogic.
- Mixing of FC SFP+ and FCoE SFP+ allowed
- Mixing of NICs allowed.
- No factory mixing of Aura 3 and Aura 6 allowed.
- No mixing of Fortville and Niantic.
|
Internal
Mass Storage |
Disks |
Eight rear-accessible and hot-swappable 2.5" SAS-2 HDDs or eight 2.5"
SATA-3 SSDs for up to 9.6TB of internal storage.
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS-2
|
600GB
|
10,000 RPM
|
2.5"
|
SAS-2
|
1.2TB
|
10,000 RPM
|
2.5"
|
SATA-3
|
400GB
|
Solid State
|
2.5"
|
|
Power
Supplies and Fans |
- Four dual redundant, hot swap power supplies and 8 Hot-swap Redundant
Dual Fans.
- Cooling is front to back.
|
Environment |
Power Consumption |
Online
power calculator |
AC power |
Nominal input frequencies 50/60 Hz
Operating input voltage range 200-240 VAC
Rated input current 23A@200 to 230 VAC 12A max per cord
Maximum power consumption 3400W |
Maximum Heat Output |
11600 BTU/hr |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°F) |
Humidity |
Operating: 10% to 90% relative humidity, noncondensing
Nonoperating: Up to 93% relative humidity, noncondensing |
Altitude |
Single, non-rack system:
Operating: Up to 3000 m (9,840 ft.), maximum operating temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft),
except in China where regulations may limit installations to a maximum altitude
of 2,000 m
Nonoperating: 0 to 12,000 m (39,370 ft.) |
Acoustic Noise Emissions |
LwAd (1B= 10dB) - 7.7 B operating, 6.8 B idling |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1, EN 60950-1, IEC 60950-1 (CB Scheme with all country differences) |
EMC |
Emissions: FCC CFR 47 Part 15, ICES-003, EN 55022, EN610000-3-2, EN61000-3-3
Immunity: EN55024 |
Emissions and Immunity |
EN300 386 |
Certifications |
Safety Marks |
North America (NRTL), European Union (EU), International CB Scheme, HSE
Exemption (India), BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan) |
European Union Directives |
2006/95/EC Low Voltage Directive, 2004/108/EC EMC Directive, 2011/65/EU
RoHS Directive, 2012/19/EU WEEE Directive |
Dimensions
and Weight |
Height |
219.25 mm (8.63 in.) 5U |
Width |
445 mm (17.5 in.) |
Depth |
834 mm (32.8 in.) |
Weight |
Maximum: 114 kg (250 lbs.) |
Rack
Mounting & Clearance |
Oracle Server X4-8 Racks
|
- Tooless Slide Rail Rackmount Kit
- Sun Rack 1242
- Front Minimum Clearance: 1,232 mm (48.5 in)
- Rear Minimum Clearance: 914 mm (36 in)
|