Processor |
Number |
2 or 4 Processors |
Architecture |
Type: Intel Xeon E7-8895 v3 Processors |
CPUs |
Intel 2.6GHz 18-Core Xeon E7-8895 v3, 175W
|
Main
Memory |
Capacities |
- 2 Processor - Up to 48 DIMMs
- 4 Processor - Up to 96 DIMMs
- DIMM Size and Type: 16GB: DDR3L-1600/PC3L-12800 Registered
DIMM or 32GB: DDR3L-1600/PC3L-12800 load-reduced DIMMs (LRDIMM)
- 2 Processor - Minimum Memory Capacity: 128GB using 16GB DIMMs
in 8 slots
- 2 Processor - Maximum Memory Capacity: 1536GB using 32GB DIMMs
in 48 slots
- 4 Processor - Minimum Memory Capacity: 256GB using 16GB DIMMs
in 16 slots
- 4 Processor - Maximum Memory Capacity: 3072GB using 32GB DIMMs
in 96 slots
|
Standard
I/O |
Network |
Four auto-negotiating 10 Gigabit Ethernet (GbE) ports (RJ-45 connector). |
Network Management |
One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port |
Serial Management |
One serial console (SER MGT/RJ-45 connector) port. |
USB |
Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports |
Video |
One VGA 2D embedded graphics controller with DB-15 connector. Resolution:
1,600 x 1,200 x 16 bits @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle
ILOM. |
I/O Expansion |
Eleven PCI Express 3.0 Slots:
- 9 slots are x8 PCIe slots (1 - 7, 9, & 10)
- 2 slots are x16 PCIe slots (8 & 11)
- 2 CPU processor configurations only support 6 PCIe slots, 1-6. Install
order = 6, 4, 5, 3, 1
- 4 CPU processor configurations support all 11 PCIe slots 1-11. Install
order = 11, 8, 6, 4, 10, 7, 5, 3, 9, 1
- PCIe slot 2 is reserved for the SAS HBA for the internal disk drives.
- No mixing of Emulex and Qlogic cards
- No mixing of FC SFP+ and FCoE SFP+
- Mixing of NICs allowed
- No factory mixing of Aura 3 and Aura 6 AIC
- No mixing of Fortville and Niantic
|
Internal
Mass Storage |
Disks |
Six front-accessible and hot-swappable 2.5"
SAS-3 disk bays and optional DVD-RW drive. Up
to four small form factor NVMe drives (6.4 TB total capacity).
Four of the disk drive bays are predesignated as NVMe enabled and
requires an Oracle NVMe enabling kit that consumes one PCIe slot.
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS-2
|
600GB
|
10,000 RPM
|
2.5"
|
SAS-2
|
1.2TB
|
10,000 RPM
|
2.5"
|
SAS-3
|
400GB
|
Solid State
|
2.5"
|
NVMe PCIe 3.0
|
1.6TB
|
Solid State
|
2.5"
|
|
Power
Supplies and Fans |
- Two hot-swappable power supplies with N=N redundancy.
|
Environment |
Power Consumption |
Online
power calculator |
AC power |
Operating input voltage range: 100 to 127 VAC (2-CPU configuration); 200
to 240 VAC (2-CPU or 4-CPU configuration)
Rated input current 100 to 127 VAC 12A and 200 to 240 VAC 10A. |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F) (sea
level); 5° C to 31° C (41° F to 88° F) (at altitude)
Nonoperating: -40° C to 68° C (-40° F to 154°F) |
Humidity |
Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: Up to 93% relative humidity noncondensing |
Altitude |
Operating: Up to 3,000 m (9,840 ft.) maximum operating temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft),
except in China where regulations might limit installations to a maximum
of 2000 m (6562 ft).
Nonoperating: Up to 12,000 m (39,370 ft.) |
Maximum Power Consumption |
2000W |
Maximum Heat Output |
6824 BTU/hr |
Acoustic Noise |
LwAd: 8.9 B (idle and operating, room temp.), 8.9 B (max. ambient); LpAm:
75 dBA (bystander position,
max. ambient) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB scheme with all country differences.
|
EMC |
Emissions: FCC 47 CFR Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3.
|
Immunity |
EM55024 |
Certifications |
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- MSIP (Korea)
- VCCI (Japan)
|
European Union Directives |
- 2014/35/EU Low Voltage Directive
- 2014/30/EU EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions
and Weight |
Height |
129.9 mm (5.1 in.) |
Width |
436.5 mm (17.2 in.) |
Depth |
732 mm (28.8 in.)
752.35 mm (29.6 in) with PSU ejectors |
Weight |
Maximum: 40 kg (88 lbs.) |
Rack
Mounting |
Clearances
| Front: 1232 mm (48.5 in)
Rear: 914 mm (36 in) |
Oracle Server X5-4 Racks
|
- Sun Rack II 1042
- Sun Rack II 1242
- Tooless rackmounting slide rail kit.
- Cable management arm.
|