Processor |
Number |
1 or 2 Processors |
Architecture |
Type: Intel Xeon E5-2600 v3 Processor Series |
CPUs |
Intel 2.4GHz 8-Core Xeon E5-2630 v3, 85W
Intel 2.6GHz 10-Core Xeon E5-2660 v3, 105W
Intel 2.6GHz 12-Core Xeon E5-2690 v3, 135W
Intel 2.3GHz 18-Core Xeon E5-2699 v3, 145W
|
Cache |
Level 1: 32 KB instruction and 32 KB data L1 cache per core
Level 2: 256 KB shared data and instruction L2 cache per core
Level 3: Up to 45 MB shared inclusive L3 cache per processor
|
Main Memory |
Capacities |
- 24 DIMM Slots
- DIMM Size and Type: 8GB: DDR4-2133 Registered DIMM, 16GB: DDR4-2133 Registered DIMM or 32GB: DDR4-2133 GHz load-reduced DIMMs (LRDIMM)
- Minimum Memory Capacity: 96GB using 8GB DIMMs in a 1 CPU configuration
- Maximum Memory Capacity: 768 GB using 32GB DIMMs in a 2 CPU configuration
|
Standard I/O |
Network |
- Four onboard auto-sensing 100/1000/10,000BASE-T gigabit Ethernet (GbE) ports (RJ-45 connector)
- Ethernet ports NET 2 and NET 3 are nonfunctional in single-processor systems
|
Network Management |
One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port |
Serial Management |
One serial console (SER MGT/RJ-45 connector) port |
USB |
Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports |
Graphics |
- One VGA 2D embedded graphics controller with DB-15 connector
- Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
|
I/O Expansion |
Six PCIe 3.0 slots:
PCIe slots 1, 2 and 3 are nonfunctional in single-processor systems
- PCI-E slot 1: x8
- PCI-E slot 2: x8
- PCI-E slot 3: x16
- PCI-E slot 4: x16
- PCI-E slot 5: x8
- PCI-E slot 6: x8
|
Internal
Mass Storage |
Disks, Flash and DVD |
Four Disk Backplanes configurations
- Eight-disk chassis: eight 2.5-inch front hot-swappable disk bays and
optional DVD-RW drive
- Twelve-disk chassis: twelve 3.5-inch front hot-swappable disk bays
and an additional two 2.5-inch rear hot-swappable disk bays
- Twelve-disk chassis: twelve 2.5-inch front hot-swappable NVMe disk bays and an additional two 2.5-inch rear hot-swappable disk bays
- Twenty-four-disk chassis: twenty-four 2.5-inch front hot-swappable
disk bays and an additional two 2.5-inch rear hot-swappable disk bays
- Up to four small form factor NVM Express (NVMe) drives (6.4 TB total
capacity) are available in eight-disk and twenty-four-disk chassis only
(slots 2 - 5 in 8-disk cage of slots 3 -4 and slots 19 - 20 in 24-disk
cage)
- Internal 8GB USB 2.0 Flash Drive
- The 2.5-inch disk bays can be populated with either HDDs, SSDs, or
NVMe
- The 3.5-inch disk bays can be populated only with HDDs
- 12 Gbps RAID HBA supporting levels: 0, 1, 5, 6, 10, 50, 60, and JBOD
with 1 GB of DDR3 onboard memory with flash memory backup via embedded
internal SAS3 HBA PCIe Card in Slot 6
- 2.5-inch drives support 600GB/10KRPM, 1.2TB/10KRPM, and 1.6TB NVMe
configurations
- 3.5-inch drives support 4TB/7200RPM configuration
- 3.5-inch drives support 8TB/7200RPM configuration
|
Power Supplies |
- Two hot-swappable and redundant power supplies, rated 91% efficiency.
|
Environment |
Power Consumption |
Online power calculator |
AC power |
Rated line voltage: 100 to 240 VAC
Rated input current 100 to 127 VAC 8.5 A and 200 to 240 VAC 5.7 A
|
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°F) |
Humidity |
Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: Up to 93% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: Up to 3,000 m (9,840 ft) maximum ambient temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft)
Nonoperating: Up to 12,000 m (39,370 ft) |
Acoustic Noise Emissions |
8.1 Bels A-weighted operating, 5.8 Bels A-weighted idling |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences
|
EMC |
Emissions: FCC CFR 47 Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3
|
Immunity |
EM55024
|
Other |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
|
Certifications |
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- CCC (PRC)
- MSIP (Korea)
- VCCI (Japan)
|
European Union Directives |
2006/95/EC Low Voltage Directive
- 2004/108/EC EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions and Weight |
Height |
87.6 mm (3.5 in.). |
Width |
445.5 mm (17.5 in.). |
Depth |
737 mm (29.0 in.). |
Weight |
8-disk configuration maximum: 24.5 kg (54 lbs.) fully populated
12-disk configuration maximum: 29.6 kg (66 lbs.) fully populated
24-disk configuration maximum: 29.0 kg (64 lbs.) fully populated
|
Rack
Mounting |
Oracle Server X5-2L Racks
|
- Tooless rackmounting slide rail kit
- Cable management arm
|