Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Server X5-2L: Hardware Specifications

Processor
Number 1 or 2 Processors
Architecture Type: Intel Xeon E5-2600 v3 Processor Series
CPUs Intel 2.4GHz   8-Core Xeon E5-2630 v3, 85W
Intel 2.6GHz 10-Core Xeon E5-2660 v3, 105W
Intel 2.6GHz 12-Core Xeon E5-2690 v3, 135W
Intel 2.3GHz 18-Core Xeon E5-2699 v3, 145W
Cache Level 1: 32 KB instruction and 32 KB data L1 cache per core
Level 2: 256 KB shared data and instruction L2 cache per core
Level 3: Up to 45 MB shared inclusive L3 cache per processor
Main Memory
Capacities
  • 24 DIMM Slots
  • DIMM Size and Type: 8GB: DDR4-2133 Registered DIMM, 16GB: DDR4-2133 Registered DIMM or 32GB: DDR4-2133 GHz load-reduced DIMMs (LRDIMM)
  • Minimum Memory Capacity: 96GB using 8GB DIMMs in a 1 CPU configuration
  • Maximum Memory Capacity: 768 GB using 32GB DIMMs in a 2 CPU configuration
Standard I/O
Network
  • Four onboard auto-sensing 100/1000/10,000BASE-T gigabit Ethernet (GbE) ports (RJ-45 connector)
  • Ethernet ports NET 2 and NET 3 are nonfunctional in single-processor systems
Network Management One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port
Serial Management One serial console (SER MGT/RJ-45 connector) port
USB Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports
Graphics
  • One VGA 2D embedded graphics controller with DB-15 connector
  • Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
I/O Expansion Six PCIe 3.0 slots: PCIe slots 1, 2 and 3 are nonfunctional in single-processor systems
  • PCI-E slot 1: x8
  • PCI-E slot 2: x8
  • PCI-E slot 3: x16
  • PCI-E slot 4: x16
  • PCI-E slot 5: x8
  • PCI-E slot 6: x8
Internal Mass Storage
Disks, Flash and DVD Four Disk Backplanes configurations
  • Eight-disk chassis: eight 2.5-inch front hot-swappable disk bays and optional DVD-RW drive
  • Twelve-disk chassis: twelve 3.5-inch front hot-swappable disk bays and an additional two 2.5-inch rear hot-swappable disk bays
  • Twelve-disk chassis: twelve 2.5-inch front hot-swappable NVMe disk bays and an additional two 2.5-inch rear hot-swappable disk bays
  • Twenty-four-disk chassis: twenty-four 2.5-inch front hot-swappable disk bays and an additional two 2.5-inch rear hot-swappable disk bays
  • Up to four small form factor NVM Express (NVMe) drives (6.4 TB total capacity) are available in eight-disk and twenty-four-disk chassis only (slots 2 - 5 in 8-disk cage of slots 3 -4 and slots 19 - 20 in 24-disk cage)
  • Internal 8GB USB 2.0 Flash Drive
  • The 2.5-inch disk bays can be populated with either HDDs, SSDs, or NVMe
  • The 3.5-inch disk bays can be populated only with HDDs
  • 12 Gbps RAID HBA supporting levels: 0, 1, 5, 6, 10, 50, 60, and JBOD with 1 GB of DDR3 onboard memory with flash memory backup via embedded internal SAS3 HBA PCIe Card in Slot 6
  • 2.5-inch drives support 600GB/10KRPM, 1.2TB/10KRPM, and 1.6TB NVMe configurations
  • 3.5-inch drives support 4TB/7200RPM configuration
  • 3.5-inch drives support 8TB/7200RPM configuration
Power Supplies
  • Two hot-swappable and redundant power supplies, rated 91% efficiency.
Environment
Power Consumption Online power calculator
AC power Rated line voltage: 100 to 240 VAC
Rated input current 100 to 127 VAC 8.5 A and 200 to 240 VAC 5.7 A
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°F)
Humidity Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: Up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3,000 m (9,840 ft) maximum ambient temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft)
Nonoperating: Up to 12,000 m (39,370 ft)
Acoustic Noise Emissions 8.1 Bels A-weighted operating, 5.8 Bels A-weighted idling
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences
EMC Emissions: FCC CFR 47 Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3
Immunity EM55024
Other Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
Certifications
  • North America Safety (NRTL)
  • European Union (EU)
  • International CB Scheme
  • BIS (India)
  • BSMI (Taiwan)
  • RCM (Australia)
  • CCC (PRC)
  • MSIP (Korea)
  • VCCI (Japan)
European Union Directives
    2006/95/EC Low Voltage Directive
  • 2004/108/EC EMC Directive
  • 2011/65/EU RoHS Directive
  • 2012/19/EU WEEE Directive
Dimensions and Weight
Height 87.6 mm (3.5 in.).
Width 445.5 mm (17.5 in.).
Depth 737 mm (29.0 in.).
Weight 8-disk configuration maximum: 24.5 kg (54 lbs.) fully populated
12-disk configuration maximum: 29.6 kg (66 lbs.) fully populated
24-disk configuration maximum: 29.0 kg (64 lbs.) fully populated
Rack Mounting
Oracle Server X5-2L Racks
  • Tooless rackmounting slide rail kit
  • Cable management arm

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.