Processor |
Number |
1 or 2 Processors |
Architecture |
Type: Intel Xeon E5-2600 v3 Processor Series |
CPUs |
Intel 2.4GHz 8-Core Xeon E5-2630 v3, 85W
Intel 2.6GHz 10-Core Xeon E5-2660 v3, 105W
Intel 2.6GHz 12-Core Xeon E5-2690 v3, 135W
Intel 2.3GHz 18-Core Xeon E5-2699 v3, 145W
|
Main Memory |
Capacities |
- 24 DIMM Slots
- DIMM Size and Type: 8GB: DDR4-2133 Registered DIMM, 16GB: DDR4-2133 Registered DIMM or 32GB: DDR4-2133 GHz load-reduced DIMMs (LRDIMM)
- Minimum Memory Capacity: 96GB using 8GB DIMMs in a 1 CPU configuration
- Maximum Memory Capacity: 768 GB using 32GB DIMMs in a 2 CPU configuration
|
Standard I/O |
Network |
Four auto-negotiating 100/1000/10,000BASE-T gigabit Ethernet (GbE) ports (RJ-45 connector). Ethernet ports NET 2 and NET 3 are nonfunctional in single-processor systems.
|
Network Management |
One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port |
Serial Management |
One serial console (SER MGT/RJ-45 connector) port. |
USB |
Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports |
Video |
One VGA 2D embedded graphics controller with DB-15 connector. Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
|
I/O Expansion |
Four PCIe 3.0 slots: three external and one internal. The internal slot is not visible
from the rear of the server and supports a required internal SAS controller HBA card.
PCIe slot 1 is nonfunctional in single-processor systems.
- PCI-E slot 1: x16 mechanical/x16 electrical
- PCI-E slot 2: x16 mechanical/x16 electrical
- PCI-E slot 3 and 4: x8 mechanical/x8 electrical
|
Internal
Mass Storage |
Disks |
Eight front-accessible and hot-swappable 2.5" disk bays and optional DVD-RW drive. Up to four small form factor NVMe drives (6.4 TB total capacity). Four of the disk drive bays are predesignated as NVMe enabled and requires an Oracle NVMe enabling kit that consumes one PCIe slot.
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS-2
|
600GB
|
10,000 RPM
|
2.5"
|
SAS-2
|
1.2TB
|
10,000 RPM
|
2.5"
|
SAS-3
|
400GB
|
Solid State
|
2.5"
|
NVMe PCIe 3.0
|
1.6TB
|
Solid State
|
2.5"
|
|
Power Supplies and Fans |
- Two hot-swappable and redundant power supplies and 4 hot-swappable and Redundant Fan Modules each with 2 fans.
- Cooling is front to back.
|
Environment |
Power Consumption |
Online power calculator |
AC power |
Rated line voltage: 100 to 240 VAC.
Rated input current 100 to 127 VAC 7.2 A and 200 to 240 VAC 3.4 A.
|
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°F) |
Humidity |
Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: Up to 93% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: Up to 3,000 m (9,840 ft.) maximum operating temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.) |
Acoustic Noise Emissions |
7.0 Bels A-weighted operating, 7.0 Bels A-weighted idling |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences.
|
EMC |
Emissions: FCC CFR 47 Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3.
|
Immunity |
EM55024.
|
Other |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
|
Certifications |
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- CCC (PRC)
- MSIP (Korea)
- VCCI (Japan)
|
European Union Directives |
- 2006/95/EC Low Voltage Directive
- 2004/108/EC EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions and Weight |
Height |
42.6 mm (1.7 in.). |
Width |
436.5 mm (17.2 in.). |
Depth |
737 mm (29.0 in.). |
Weight |
Maximum: 18.1 kg (40 lbs.) fully populated. |
Rack
Mounting |
Oracle Server X5-2 Racks
|
- Tooless rackmounting slide rail kit.
- Cable management arm.
|