Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Network Applications Platform - General Hardware Specifications

Oracle Network Applications Platform: General Hardware Specifications


Supported Hardware Configurations
Dual Compute Configuration - Two Sun Netra 6000 Modular System Chassis's, each with Ten Netra Blade X3-2B Server Modules. Netra 6000 Chassis #1 contains Two Management Blades and Eight Compute Blades. Netra 6000 Chassis #2 contains Ten Compute Blades.
Compute Full Storage Configuration - One Sun Netra 6000 Modular System Chassis, which contains Two Management Blades and Eight Compute Blades, Two Sun ZFS 7320 Controllers and Four Sun Disk Shelves 24 × 3.5" SAS-2. (48TB of Storage)
Compute Half Storage Configuration - One Sun Netra 6000 Modular System Chassis, which contains Two Management Blades and Eight Compute Blades, Two Sun ZFS 7320 Controllers and Two Sun Disk Shelves 24 × 3.5" SAS-2. (24TB of Storage)
Key Features
  • Integrated hardware and software stack.
  • Unified Management and Configuration with Oracle Enterprise Manager
  • Unified Availability via integration of Oracle Communications Service Availability software and Oracle Clusterware.
  • Carrier-grade Sun Netra hardware with Oracle Linux 5.8
  • Applications
  • IMS - Media gateway controller, Multi-media session control, Wireless media gateway, Call session control functions.
  • NGIN - MMS, SMS, Messaging, AAA, SDP, Video transcoding (IPTV), Home and mobile device management, Subscriber management.
  • OSS - Next generation/ Unified OSS, Policy Control & Charging (PCC), Machine-to-Machine (M2M), Real-time Charging/Online Charging Systems (RTC/OCS).

  • Sun ZFS Storage 7320: Hardware Specifications

    Processor
    Number 2 Quad-Core
    Architecture Type: Intel Xeon Quad-Core Processor
    CPUs Intel 2.40GHz Quad-Core Xeon E5620 (12MB L3, 80W)
    Main Memory
    Capacities Total DIMM slots: 18
    DIMM type: DDR3 1333MHz Registered DIMMs
    DIMM size: 8-GB 1333MHz
    Maximum capacity: 144GB
    Standard Integrated Interfaces
    Network Four 10/100/1000 Base-T Ethernet Ports
    Network Management One dedicated 10/100Base-T Ethernet port
    Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
    USB Front: Two USB 2.0 ports
    Rear: Two USB 2.0 ports
    Internal: One USB 2.0 port (for a 4GB USB thumb drive)
    PCI Expansion Slots Three low profile PCI Express 2.0 slots (1 x16 electrical/mechanical, 2 x8 electrical/mechanical)
    Internal Mass Storage
    Disks SAS: Twenty-four 3.5" SAS Disks in the Disk Shelf
    SATA-2: Eight 2.5" SATA Disks in the ZFS 7320
    Drive Type
    Density
    Speed
    Form Factor
    Supported in
    SATA
    500GB
    10,000 RPM
    2.5"
    ZFS 7320
    SSD (Solid State Drives) SATA
    512GB
    NA
    2.5"
    ZFS 7320
    SAS
    600GB
    15,000 RPM
    3.5"
    Disk Shelf
    SSD (Solid State Drives) SAS-2
    73GB
    NA
    3.5"
    Disk Shelf
    Power Supplies
    Dual redundant, hot swappable power supplies
    (Power supply rating output = 760W)
    (UL Maximum AC input = 760W x 1.33 efficiency = 1010W)
    (9.0 Amps RMS at 100 VAC)
    Environment
    AC power 100-120 / 200-240 VAC (50-60 Hz)
    Temperature Single, non-rack system:
    Operating: 5° C to 35° C (41° F to 95° F)
    Nonoperating: -40° C to 70° C (-40° F to 158° F)
    Humidity Single, non-rack system:
    Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
    Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
    Altitude Single, non-rack system:
    Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
    Nonoperating: up to 12,000 m (40,000 ft.)
    Regulations
    Meets or exceeds the following requirements:
    Safety UL 60950-1 2nd Ed, EN60950-1:2006 2nd Ed, CB Scheme with all country differences
    RFI/EMI FCC CFR 47 Part 15 Subpart B Class A, EN55022:2006+A1:2007 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
    Immunity EN55024, EN300-386
    Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
    EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
    Dimensions and Weight
    Height 43.43 mm (1.71 in.)
    Width 425.5 mm (16.75 in.)
    Depth 685.8 mm (27.0 in.)
    Weight 16.36 kg (36 lb.) maximum assuming PCI-Express card weighs 0.12 kg
    (0.25 lb) each, and without the rack mounting slide rail kit installed.
    Rack Mounting
    Oracle Network Applications Platform Racks Racks are as follows:
    • Sun Rack II 1042
    • Sun Rack II 1242

    Netra Blade X3-2B Server Module: Hardware Specifications

    Note: Modular System (chassis) specifications are documented on the chassis specification page. Reference the Sun Netra 6000 Modular System section of the Handbook's Systems List to find documentation on the chassis.
    Processor
    Number Two.
    Architecture Type:Eight-core, Intel[tm] Xeon E5-2600 series processors.
    • Model/Speed/Watts: E5-2658, 2.1 GHz, 95W
    Cache Memory Level 1: 32 KB instruction and 32 KB data L1 cache per core.
    Level 2: 256 KB shared instruction/data L2 cache per core.
    Level 3: Up to 20 MB shared inclusive L3 cache per processor.
    Main Memory
    Memory Type DDR3-1066 DIMMs.
    Capacities
    • Total DIMM slots: 24.
    • DIMM type: DDR3 1066MHz DIMMs
    • DIMM size: 16 GB.
    • Maximum capacity: 384GB
    Internal Storage
    Disk
    • Four, hot swappable, Small Form Factor (SFF) 2.5" drive bays per Server Module. Four SAS-2 interfaces to the midplane, two to each Network Express Module slot. Note: RAID Expansion Module is required for SAS support.
      Drive Type
      Density
      Speed
      Form Factor
      SAS
      600 GB
      10,000 RPM
      2.5"
    Management Environment
    Server Module Service Processor (SP)
    • Oracle Integrated Lights Out Manager (Oracle ILOM) provides:
      • Remote Keyboard, Video, Mouse redirection.
      • Full remote management through command-line, IPMI, and browser interfaces.
      • Remote media capability (DVD, CD, ISO image, floppy).
      • Advanced power management and monitoring.
      • Active Directory, LDAP, RADIUS support.
    Interfaces
    • Dedicated 10/100 Base-T Ethernet network management port.
    • In-band, out-of-band and sideband network management access via any one of the four main ports of the server or the dedicated port.
    • RJ-45 serial management port.
    Monitoring
    • Comprehensive fault detection and notification.
    • In-band, out-of-band, and side-band SNMP monitoring V1, V2c, V3.
    • Syslog and SMTP alerts, WS-MAN.
    • Automatically create a service request for key hardware faults with Oracle Automated Service Request (ASR).
    Standard Integrated Interfaces
    Front Panel I/O The Dongle Cable assembly connects to the UCP and provides the following:
    • Connection to ILOM SP.
    • Dual USB 2.0 ports.
    • VGA video connection to an on-board AST2100 graphics chip.
    Network Management One dedicated 10/100Base-T Ethernet port to the CMM.
    Ethernet Two 10/100/1000Base-T Gigabit Ethernet ports interfaces, one interface to each Network Express Module slot.
    PCI Interfaces with the Sun Netra Modular System (chassis)
    • I/O is offered in two form factors:
      • PCI Express ExpressModules (EM)
        and
      • PCI Express Network Express Module.
    • Each Netra Blade X3-2B / Sun Netra X6270 M3 has four, PCI Express Gen 2 links allocated to:
      • Two EMs
        and
      • Two NEMs
    Graphics
    • 2D graphics controller with 8 MB video memory embedded inside service processor.
    • Supports resolutions up to 1,600 x 1,200 x 16 bits @60 Hz (1,024 x 768 when viewed remotely via Oracle ILOM RKVMS).
    Regulations
    NEBS[tm] Compliance Level NEBS Level 3 certification and ETSI compliance
    Dimensions and Weights
    Height 44.5mm (1.8 in).
    Width 327.2mm (12.9 in).
    Depth 511.7mm (20.1 in).
    Weight 7.9 kg (17.4 lbs) fully populated.

      Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
     Feedback