Processor |
Netra SPARC T4-1 based version
|
SPARC T7-1 based version
|
Number |
One 4-Core |
One 32-Core |
Architecture |
Type:SPARC T4 |
Type: SPARC M7 |
CPUs |
4-Core SPARC T4 2.85GHz |
32-Core SPARC M7 4.13GHz |
Main Memory |
Netra SPARC T4-1 based version
|
SPARC T7-1 based version
|
Capacities |
DIMM type: DDR3L
DIMM size: 8GB
Maximum supported capacity: 32GB Although there are 16 DIMM slots,
the OKM 3 is limited to four 8GB DIMMs
|
DIMM type: DDR4-2133
DIMM size: 16GB
Maximum supported capacity: 128GB (8x 16GB DIMMs) |
Standard Integrated Interfaces
|
Netra SPARC T4-1 based version
|
SPARC T7-1 based version
|
Network |
4 × 10/100/1000 Mbps auto negotiating ports
Up to 2 optional 10 GbE XAUI connections |
4 × 10GbE ethernet ports |
Network Management |
One dedicated 10/100Base-T RJ-45 Ethernet
port |
n/a |
Serial Management |
One dedicated RJ-45 port |
One dedicated RJ-45 port |
Remote Management |
Onboard system processor, running Integrated
Lights Out Manager (ILOM) |
Onboard system processor, running Integrated Lights Out Manager
(ILOM) |
Graphics |
One HD-15 VGA connector |
One HD-15 VGA connector |
USB |
Front:
2 USB 2.0 Ports (disabled)
Rear: 2 USB 2.0 Ports (disabled) |
n/a |
PCI Expansion Slots |
- Five PCIe Gen2 x8 slots (including support of
two full height half length PCIe cards slots and three low profile cards
slots or two XAUI)
- Slots 0 and 1 support PCI-Express or XAUI cards.
Slot # |
Physical |
Electrical |
0 |
x8 |
x8 |
1 |
x8 |
x8 |
2 |
x8 |
x8 |
3 |
x16 |
x8 |
4 |
x16 |
x8 |
|
- 6 PCIe Gen 3 adapter slots (8 lanes each)
Slot # |
Physical |
Electrical |
1 |
x8 |
x8 |
2 |
x8 |
x8 or unused if slot 3 x16 |
3 |
x16 |
x8 or x16 |
4 |
x16 |
x8 or x16 |
5 |
x8 |
x8 or unused if slot 4 x16 |
6 |
x8 |
x8 |
|
Crypto Accelerator |
Netra SPARC T4-1 based version
|
SPARC T7-1 based version
|
Device |
Oracle SCA 6000 Cryptographic Accelerator Card, 8-Lane PCI
Express |
Oracle SCA 6000 Cryptographic Accelerator Card, 8-Lane PCI
Express |
Number |
One |
One (optional). Must be installed in PCIe slot 5 if used. |
Internal Mass Storage |
Netra SPARC T4-1 based version
|
SPARC T7-1 based version
|
Disks |
SAS: One 600GB - 10000 RPM Disk |
SAS: One 600GB SAS-3 10000 RPM 2.5" Disk |
DVD-ROM |
One SATA DVD+/-RW drive - (disabled) |
n/a |
Power Supplies |
Netra SPARC T4-1 based version
|
SPARC T7-1 based version
|
2 × 1200 Watt (Type A249A AC or
Type D204A DC), hot-swappable, N+1 redundant power supply units (PSU)
|
Environment |
Netra SPARC T4-1 based version
|
SPARC T7-1 based version
|
Input Voltage |
(AC) 100 - 240 VAC, 50-60Hz
(DC) -48 VDC or -60 VDC |
(AC) 200 - 240 VAC, 50-60Hz |
Temperature |
Operating: 5° C to 45° C (41° F to 113° F)
Short Term Operating: -5° C to 55° C (23° F to 131°
F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Operating (max): 5° C to 35° C (41° F to
95° F) |
Humidity |
Operating: 5% to 85% relative humidity noncondensing
Short Term Operating: 5% to 90% relative humidity noncondensing,
but not to exceed 0.024 kg water/kg dry air (0.053 lb. water/2.205 lbs.
dry air)
Nonoperating: 93% relative humidity noncondensing, 40° C, 104°
F) maximum wet bulb |
Operating: 10% to 90% at 27° C (81° F); relative
humidity noncondensing, max wet bulb |
Altitude |
Operating: Meets NEBS 4000m (13,123 ft) requirement
Nonoperating: up to 12000m (39,370 ft.) |
Operating: 0 m to 3000 m at 40° C (0 to 9840 ft.
at 95° F)
Note: China market regulations might limit installations to a maximum altitude
of 2 km. |
Seismic |
GR-63-CORE requirements for Earthquake Zone 4 |
n/a |
Acoustic Noise |
Operating/Idling: 7.2 B (LwAd, 1B = 10dB) |
Operating/Idling: 62.0 dBA (LwAd, 1B = 10dB)
Operating/Idling: 69.7 dBA (LpAm, bystander positions) |
NEBS |
NEBS Level3 certified by Telecordia |
n/a |
Regulations
Meets or exceeds the following requirements: |
Netra SPARC T4-1 based version
|
SPARC T7-1 based version
|
Safety |
UL/CSA C22.2 60950-1, 2nd Edition EN 60950-1, 2nd Edition,
IEC 60950-1 :2005 2nd Edition CB Scheme with all national differences, IEC
825-1,2 and CFR21 part 1040 |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country
deviations |
RFI/EMI |
EN55022:2006+A1:2007/CISPR22:2005+A1:2005+A2:2006 EN300 386
V1.4.1 Class A, FCC CFR 47 Part 15 Class A |
EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI
Class A, AS/NZ3548 Class A, CNS 13438 Class A, KSC 5858 Class A, EN61000-3-2,
EN61000-3-3 |
Immunity |
EN55024/CISPR 24, EN 61000-3-2, EN 61000-3-3, EN300-386 |
EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC
61000-4-5,
IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 |
Regulatory Markings |
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL,
S-mark, CCC |
n/a |
Other |
Restriction of Hazardous Substances (RoHS) labeled,
per WEEE (Waste Electrical and Electronics Equipment) Directive (2002/95/EC) |
2006/95/EC (73/23/EEC) Low Voltage Directive,
2014/35/EU EMC Directive, 2014/30/EU, Waste Electrical and Electronic Equipment
Directive (WEEE) 2012/19/EU Directive, 2002/95/EC Restriction of Hazardous
Substances (RoHS) Directive 2011/65/EU |
Telecommunications |
EN 300 386 |
n/a |
Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
|
North American Safety (NRTL), European Union (EU), International
CB Scheme, BIS (India),
BSMI (Taiwan), RCM (Australia), CCC (PRC), MSIP (Korea), VCCI (Japan) |
Dimensions and Weight |
Netra SPARC T4-1 based version
|
SPARC T7-1 based version
|
Height |
87.1 mm (3.43 in.) |
87.6 mm (3.45 in.) |
Width |
445 mm (17.52 in.) |
445 mm (17.52 in.) |
Depth |
526 mm (20.71 in.) max to PSU handles |
737 mm (29 in.) |
Weight |
18.6 kg (41 lbs.) - fully configured without PCI cards installed
|
25.6 kg (56 lbs.) |