Processor
Netra SPARC T4-1 based version
SPARC T7-1 based version
Number One 4-Core One 32-Core
Architecture Type:SPARC T4 Type: SPARC M7
CPUs 4-Core SPARC T4 2.85GHz 32-Core SPARC M7 4.13GHz
Main Memory
Netra SPARC T4-1 based version
SPARC T7-1 based version
Capacities DIMM type: DDR3L
DIMM size: 8GB
Maximum supported capacity: 32GB Although there are 16 DIMM slots, the OKM 3 is limited to four 8GB DIMMs
DIMM type: DDR4-2133
DIMM size: 16GB
Maximum supported capacity: 128GB (8x 16GB DIMMs)
Standard Integrated Interfaces
Netra SPARC T4-1 based version
SPARC T7-1 based version
Network 4 × 10/100/1000 Mbps auto negotiating ports
Up to 2 optional 10 GbE XAUI connections
4 × 10GbE ethernet ports
Network Management One dedicated 10/100Base-T RJ-45 Ethernet port n/a
Serial Management One dedicated RJ-45 port One dedicated RJ-45 port
Remote Management Onboard system processor, running Integrated Lights Out Manager (ILOM) Onboard system processor, running Integrated Lights Out Manager (ILOM)
Graphics One HD-15 VGA connector One HD-15 VGA connector
USB Front: 2 USB 2.0 Ports (disabled)
Rear: 2 USB 2.0 Ports (disabled)
n/a
PCI Expansion Slots
  • Five PCIe Gen2 x8 slots (including support of two full height half length PCIe cards slots and three low profile cards slots or two XAUI)
  • Slots 0 and 1 support PCI-Express or XAUI cards.
Slot # Physical Electrical
0 x8 x8
1 x8 x8
2 x8 x8
3 x16 x8
4 x16 x8
  • 6 PCIe Gen 3 adapter slots (8 lanes each)
Slot # Physical Electrical
1 x8 x8
2 x8 x8 or unused if slot 3 x16
3 x16 x8 or x16
4 x16 x8 or x16
5 x8 x8 or unused if slot 4 x16
6 x8 x8

 

Crypto Accelerator
Netra SPARC T4-1 based version
SPARC T7-1 based version
Device Oracle SCA 6000 Cryptographic Accelerator Card, 8-Lane PCI Express Oracle SCA 6000 Cryptographic Accelerator Card, 8-Lane PCI Express
Number One One (optional). Must be installed in PCIe slot 5 if used.
Internal Mass Storage
Netra SPARC T4-1 based version
SPARC T7-1 based version
Disks SAS: One 600GB - 10000 RPM Disk SAS: One 600GB SAS-3 10000 RPM 2.5" Disk
DVD-ROM One SATA DVD+/-RW drive - (disabled) n/a
Power Supplies
Netra SPARC T4-1 based version
SPARC T7-1 based version
2 × 1200 Watt (Type A249A AC or Type D204A DC), hot-swappable, N+1 redundant power supply units (PSU)
Environment
Netra SPARC T4-1 based version
SPARC T7-1 based version
Input Voltage (AC) 100 - 240 VAC, 50-60Hz
(DC) -48 VDC or -60 VDC
(AC) 200 - 240 VAC, 50-60Hz
Temperature

Operating: 5° C to 45° C (41° F to 113° F)
Short Term Operating: -5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)

Operating (max): 5° C to 35° C (41° F to 95° F)
Humidity Operating: 5% to 85% relative humidity noncondensing
Short Term Operating: 5% to 90% relative humidity noncondensing, but not to exceed 0.024 kg water/kg dry air (0.053 lb. water/2.205 lbs. dry air)
Nonoperating: 93% relative humidity noncondensing, 40° C, 104° F) maximum wet bulb
Operating: 10% to 90% at 27° C (81° F); relative humidity noncondensing, max wet bulb
Altitude Operating: Meets NEBS 4000m (13,123 ft) requirement
Nonoperating: up to 12000m (39,370 ft.)
Operating: 0 m to 3000 m at 40° C (0 to 9840 ft. at 95° F)
Note: China market regulations might limit installations to a maximum altitude of 2 km.
Seismic GR-63-CORE requirements for Earthquake Zone 4 n/a
Acoustic Noise Operating/Idling: 7.2 B (LwAd, 1B = 10dB) Operating/Idling: 62.0 dBA (LwAd, 1B = 10dB)
Operating/Idling: 69.7 dBA (LpAm, bystander positions)
NEBS NEBS Level3 certified by Telecordia n/a
Regulations
Meets or exceeds the following requirements:
Netra SPARC T4-1 based version
SPARC T7-1 based version
Safety UL/CSA C22.2 60950-1, 2nd Edition EN 60950-1, 2nd Edition, IEC 60950-1 :2005 2nd Edition CB Scheme with all national differences, IEC 825-1,2 and CFR21 part 1040 UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations
RFI/EMI EN55022:2006+A1:2007/CISPR22:2005+A1:2005+A2:2006 EN300 386 V1.4.1 Class A, FCC CFR 47 Part 15 Class A EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ3548 Class A, CNS 13438 Class A, KSC 5858 Class A, EN61000-3-2, EN61000-3-3
Immunity EN55024/CISPR 24, EN 61000-3-2, EN 61000-3-3, EN300-386 EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, S-mark, CCC n/a
Other Restriction of Hazardous Substances (RoHS) labeled, per WEEE (Waste Electrical and Electronics Equipment) Directive (2002/95/EC) 2006/95/EC (73/23/EEC) Low Voltage Directive, 2014/35/EU EMC Directive, 2014/30/EU, Waste Electrical and Electronic Equipment Directive (WEEE) 2012/19/EU Directive, 2002/95/EC Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU
Telecommunications EN 300 386 n/a
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
North American Safety (NRTL), European Union (EU), International CB Scheme, BIS (India),
BSMI (Taiwan), RCM (Australia), CCC (PRC), MSIP (Korea), VCCI (Japan)
Dimensions and Weight
Netra SPARC T4-1 based version
SPARC T7-1 based version
Height 87.1 mm (3.43 in.) 87.6 mm (3.45 in.)
Width 445 mm (17.52 in.) 445 mm (17.52 in.)
Depth 526 mm (20.71 in.) max to PSU handles 737 mm (29 in.)
Weight 18.6 kg (41 lbs.) - fully configured without PCI cards installed 25.6 kg (56 lbs.)