Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Database Appliance X7-2M (Medium): Hardware Specifications

Processor
Number 2 Processors
Architecture Type: Intel Xeon G-6140 Processor Series
CPUs Intel 2.3GHz 18-Core Xeon G-6140, 140W SR3AX
Main Memory
Capacities
  • 24 DIMM Slots (12 DIMM slots are populated, expandable to 24 DIMM slots)
  • DIMM Size and Type:32GB: DDR4-2666 Registered DIMM
  • Maximum Memory Capacity: 384GB using 32GB DIMMs x 12 slots
  • Optional Memory Expansion: 768GB using 32GB DIMMs x 24 slots
Standard I/O
Network Two 10GBASE-T Ethernet ports (RJ-45 connector) or Two 10/25 GbE ports (SFP28)
Network Management One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port
Serial Management One serial console (SER MGT/RJ-45 connector) port.
USB Rear: 1 USB 3.0 Port
Internal: 1 USB 3.0 Port
I/O Expansion Four PCIe 3.0 slots: three external and one internal.
  • PCI-E slot internal slot: Internal SAS HBA
  • PCI-E slot 1: Non-functional
  • PCI-E slot 2: NVMe Switch PCIe card
  • PCI-E slot 3: Dual-port 10GbE SFP+ PCIe card
  • Note: No additional cards may be added.
Internal Mass Storage
Disks Eight front-accessible and hot-swappable 2.5" disk bays (four disk bays used in base config, expandable to 32TB and 51.2TB configs ).

Drive Type
Density
Speed
Form Factor
SATA-3
480GB
Flash Solid State
M.2
NVMe PCIe 3.0
6.4TB
NVMe Solid State
2.5"

Power Supplies and Fans
  • Two 1200W hot-swappable and redundant power supplies and 4 hot-swappable and Redundant Fan Modules each with 2 fans.
  • Cooling is front to back.
Environment
Power Consumption Online power calculator
AC power Rated line voltage: 100 to 240 VAC.
Rated input current 100 to 127 VAC 7.2 A and 200 to 240 VAC 3.4 A.
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 68° C (-40° F to 154°F)
Humidity Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: 5% to 90% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3,000 m (9,840 ft.) maximum operating temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.)
Acoustic Noise Emissions 7.1 Bels A-weighted operating, 7.0 Bels A-weighted idling
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences.
EMC Emissions: FCC CFR 47 Part 15, ICES-003, EN55022, EN55032, KN32, EN61000-3-2 and EN61000-3-3.
Immunity EM55024, KN35
Other Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
Certifications
  • North America Safety (NRTL)
  • European Union (EU)
  • International CB Scheme
  • BIS (India)
  • BSMI (Taiwan)
  • RCM (Australia)
  • CCC (PRC)
  • MSIP (Korea)
  • VCCI (Japan)
  • Morocco
  • Republic of Srpska
European Union Directives
  • 2014/35/EU Low Voltage Directive
  • 2014/30/EC EMC Directive
  • 2011/65/EU RoHS Directive
  • 2012/19/EU WEEE Directive
Dimensions and Weight
Height 42.6 mm (1.7 in.) 1U.
Width 482 mm (18.9 in.).
Depth 737 mm (29.0 in.).
Weight Maximum: 18.1 kg (40 lbs.) fully populated.
Rack Mounting
Included ODA X7-2M Rack Installation Kits
  • Snap-In Slide Rail Rackmount Kit.
  • Cable Management Arm (Snap-In).

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback