Processor |
Number |
Two 18-Core CPU's per Oracle Server X7-2 |
Architecture |
Type: Intel Xeon 18-Core Processor |
CPUs |
Intel 2.3GHz 18-Core Xeon Gold G-6140 SR3AX, 140W, XCC, 24.75MB L3 cache |
System Architecture |
Two Oracle X7-2 servers and One DE3-24C storage shelf per system
NOTE: Optional second DE3-24C storage shelf may be added for storage expansion |
Main Memory |
Capacities |
Total DIMM slots: 12 ( per Oracle Server X7-2 - not all slots are populated)
DIMM type: DDR4-2666MHz DIMMs
DIMM size: 32GB
Minimum capacity: 384GB ( 12 x 32GB per Oracle Server X7-2)
Optional: Memory expansion to 768GB (24 x 32GB) per server
Note: Both servers must contain the same amount of memory
|
Standard
Integrated Interfaces |
Network |
Two 10G Base-T Ethernet ports (RJ-45 connector) or Two 10/25 GbE ports (SFP28) per server
|
Network Management |
One 10/100/1000 M Base-T Network Management (NET MGT/RJ-45 connector) port. |
Serial Management |
One serial console (SER MGT/RJ-45 connector) port. |
System Processor |
Oracle Integrated Lights Out Manager (Oracle ILOM) provides:
Remote Keyboard, Video, Mouse redirection
Full remote management through command-line, IPMI, and browser interfaces
Remote media capability (USB, DVD, CD, ISO image)
Advanced power management and monitoring
Active Directory, LDAP, RADIUS support
Dual Oracle ILOM flash
Direct virtual media redirection (FIPS 140-2 mode using OpenSSL FIPS certification #1747)
|
USB |
Rear: One USB 3.0 port
Internal: One USB 3.0 port |
PCI Expansion Slots |
Three PCIe 3.0 slots per server:
PCIe slot 3: dual-port external SAS HBA
PCIe slot 2: dual-port external SAS HBA
PCIe slot 1: dual-port 25 GbE PCIe card (Interconnect)
|
Internal Mass Storage |
Disks |
Storage DE3-24C: Base system storage shelf contains four SSD's for REDO and five SSD's for DATA
Additional SSD's must be added in groups of five
HDDs must be added in groups of fifteen to fully populate the entire DE3-24C
Oracle Server X7-2: Two 2.5" 480GB SAS-3 SDDs. (mirrored per server for OS and Oracle Database software)
|
Power Supplies |
Two Dual redundant, hot swappable power supplies per server, rated 91% efficiency
(Power supply rating output = 1200W @ 100-127VAC/200-240VAC)
(AC power: Maximum AC input current at 100VAC and 1200W output: 7.2A)
|
Environment |
Power Consumption |
Online power calculator |
AC power |
Rated line voltage: 100 to 240 VAC.
Rated input current 100 to 127 VAC 7.2A and 200 to 240 VAC 3.4A.
|
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°F) |
Humidity |
Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: 5 to 90% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: Up to 3,000 m (9,840 ft.) maximum operating temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.) |
Acoustic Noise Emissions |
7.1 Bels A-weighted operating, 7.0 Bels A-weighted idling |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences.
|
EMC |
Emissions: FCC CFR 47 Part 15, ICES-003, EN55022, EN55032, EN61000-3-2 and EN61000-3-3.
|
Immunity |
EM55024, KN35
|
Other |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
|
Certifications |
- North America Safety (NRTL)
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- CCC (PRC)
- MSIP (Korea)
- VCCI (Japan)
- Morocco
- Republic of Srpska
|
European Union Directives |
- 2014/35/EU Low Voltage Directive
- 2014/30/EC EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions and Weight |
Height |
42.6 mm (1.7 in.) per server, 175 mm (6.9 in) per storage shelf. |
Width |
436.5 mm (17.2 in.) per server, 446 mm (17.6 in) per storage shelf. |
Depth |
737 mm (29.0 in.) per server, 558 mm (22.0 in) per storage shelf. |
Weight |
16.1 kg (34.5 lbs.) per server, 38 kg (84 lbs) per storage shelf. |
Rack
Mounting |
Included Oracle Server X7-2 Rack Installation Kits
|
- Snap-In Rail Rackmount Kit.
- Cable Management Arm (Snap-In).
|