Processor |
Number |
2 Processors |
Architecture |
Type: Intel Xeon E5-2600 v4 Processor Series |
CPUs |
Intel 2.2GHz 10-Core Xeon E5-2630 v4, 85W
|
Main Memory |
Capacities |
- 24 DIMM Slots ( not all slots are populated)
- DIMM Size and Type: 32GB: DDR4-2400 Registered DIMM
- Maximum Memory Capacity: 256GB using 32GB DIMMs x 8 slots in a 2 CPU configuration
NOTE: Optional memory expansion to 512GB (16 x 32GB) or 768GB (24 x 32GB)
|
Standard I/O |
Network |
Four auto-negotiating 100/1000/10,000 BASE-T gigabit Ethernet (GbE) ports (RJ-45 connector).
|
Network Management |
One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port |
Serial Management |
One serial console (SER MGT/RJ-45 connector) port. |
USB |
Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports |
Video |
One VGA 2D embedded graphics controller with DB-15 connector. Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
|
I/O Expansion |
Four PCIe 3.0 slots: three external and one internal. The internal slot is not visible
from the rear of the server and supports a required internal SAS controller HBA card.
- PCI-E slot 1: x16 mechanical/x16 electrical
- PCI-E slot 2: x16 mechanical/x16 electrical
- PCI-E slot 3 and 4: x8 mechanical/x8 electrical
|
Internal
Mass Storage |
Disks |
Eight front-accessible and hot-swappable 2.5" disk bays.
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS-3
|
480GB
|
Solid State
|
2.5"
|
NVMe PCIe 3.0
|
3.2TB
|
Solid State
|
2.5"
|
|
Power Supplies and Fans |
- Two hot-swappable and redundant power supplies and 4 hot-swappable and Redundant Fan Modules each with 2 fans.
- Cooling is front to back.
|
Environment |
Power Consumption |
Online power calculator |
AC power |
Rated line voltage: 100 to 240 VAC.
Rated input current 100 to 127 VAC 7.2 A and 200 to 240 VAC 3.4 A.
|
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°F) |
Humidity |
Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: Up to 93% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: Up to 3,000 m (9,840 ft.) maximum operating temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.) |
Acoustic Noise Emissions |
7.0 Bels A-weighted operating, 7.0 Bels A-weighted idling |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences.
|
EMC |
Emissions: FCC CFR 47 Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3.
|
Immunity |
EM55024.
|
Other |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
|
Certifications |
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- CCC (PRC)
- MSIP (Korea)
- VCCI (Japan)
|
European Union Directives |
- 2006/95/EC Low Voltage Directive
- 2004/108/EC EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions and Weight |
Height |
42.6 mm (1.7 in.). |
Width |
436.5 mm (17.2 in.). |
Depth |
737 mm (29.0 in.). |
Weight |
Maximum: 18.1 kg (40 lbs.) fully populated. |
Rack
Mounting |
Included ODA X6-2M Rack Installation Kits
|
- Tooless rackmounting slide rail kit.
- Cable management arm.
|