Processor |
Number |
2 Processors |
Architecture |
Type: Intel Xeon E5-2600 v4 Processor Series |
CPUs |
10-Core 2.2GHz Intel E5-2630 v4, 85W
|
Cache |
Level 1: 32 KB instruction and 32 KB data L1 cache per core
Level 2: 256 KB shared data and instruction L2 cache per core
Level 3: 25 MB shared inclusive L3 cache per processor
|
Main Memory |
Capacities |
- 24 DIMM Slots (not all slots are populated)
- DIMM Size and Type: 32GB: DDR4-2400 DIMMs
- Maximum Memory Capacity: 256GB using 32GB DIMMs x 8 Slots in a 2 CPU configuration
- NOTE: Optional memory expansion to 512GB (16 x 32GB) or 768GB (24 x 32GB)
|
Standard I/O |
Network |
- Four onboard auto-sensing 100/1000/10,000 BASE-T gigabit Ethernet (GbE) ports (RJ-45 connector)
|
Network Management |
One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port |
Serial Management |
One serial console (SER MGT/RJ-45 connector) port |
USB |
Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports |
Graphics |
- One VGA 2D embedded graphics controller with DB-15 connector
- Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
|
I/O Expansion bus |
Six PCIe 3.0 slots:
- PCI-E slot 1: x8 (Dual-Port 10GbE SFP+ PCIe card)
- PCI-E slot 2: x8 (NVMe Switch PCIe card)
- PCI-E slot 3: x16 (Dual-Port Internal SAS HBA)
- PCI-E slot 4: x16 (empty slot)
- PCI-E slot 5: x8 (MVMe Switch PCIe card)
- PCI-E slot 6: x8 (NVMe Switch PCIe card)
- NOTE: No additional cards may be added.
|
Internal
Mass Storage |
Disks |
- Twelve 3.5-inch front hot-swappable disk bays
and an additional two 2.5-inch rear hot-swappable disk bays
- Internal 8GB USB 2.0 Flash Drive
- Two 2.5-inch Rear disk bays are populated with 480GB SSDs (mirrored for OS & Oracle Database software)
- Six 3.5-inch disk bays are populated with 3.2TB SSDs (19.2TB raw capacity, 9.2TB double-mirrored, 6.4TB triple-mirrored)
- Optional: Nine 3.5-inch disk bays are populated with 3.2TB SSDs (28.8TB raw capacity, 14.4TB double-mirrored, 9.6TB triple-mirrored)
|
Power Supplies |
- Two hot-swappable and redundant power supplies, rated 91% efficiency.
|
Environment |
Power Consumption |
Online power calculator |
AC power |
Rated line voltage: 100 to 240 VAC
Rated input current 100 to 127 VAC 8.5 A and 200 to 240 VAC 5.7 A
|
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°F) |
Humidity |
Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: Up to 93% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: Up to 3,000 m (9,840 ft) maximum ambient temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft)
Nonoperating: Up to 12,000 m (39,370 ft) |
Acoustic Noise Emissions |
8.1 Bels A-weighted operating, 5.8 Bels A-weighted idling |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences
|
EMC |
Emissions: FCC CFR 47 Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3
|
Immunity |
EM55024
|
Other |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
|
Certifications |
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- CCC (PRC)
- MSIP (Korea)
- VCCI (Japan)
|
European Union Directives |
2006/95/EC Low Voltage Directive
- 2004/108/EC EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions and Weight |
Height |
87.6 mm (3.5 in.). |
Width |
445.5 mm (17.5 in.). |
Depth |
737 mm (29.0 in.). |
Weight |
29.0 kg (64.0 lbs.) fully populated
|
Rack
Mounting |
ODA X6-2L Rack Installation Kits
|
- Tooless rackmounting slide rail kit