Processor |
Number |
Two 18-Core CPU's per Sun Server X5-2 |
Architecture |
Type: Intel Xeon 18-Core Processor |
CPUs |
Intel 2.3 GHz 18-Core Xeon E5-2699 v3, 145W |
Cache per Processor |
Level 1: 32 KB instruction and 32 KB data L1 cache per core
Level 2: 256 KB shared data and instruction L2 cache per core
Level 3: Up to 45 KB shared inclusive L3 cache per processor |
Main Memory |
Capacities |
Total DIMM slots: 24 ( per Sun Server X5-2)
DIMM type: DDR4 2133MHz Load Reduced DIMMs
DIMM size: 32-GB 2133MHz
Minimum capacity: 256GB ( 8 x 32GB per Sun Server X5-2)
Maximum capacity: 768GB ( 24 x 32GB per Sun Server X5-2)
|
Standard
Integrated Interfaces |
Network |
Supports Four on-board auto-sensing 100/1000/10000 Base-T Ethernet Ports per Sun Server X5-2
|
Network Management |
Dedicated 10/100/1000 Base-T Ethernet network management port. |
Serial Management |
One RS-232 RJ45 serial port |
Video |
One rear panel high-density HD-15 video port, VGA 2-D embedded graphics controller, support for
resolutions of up to 1,600 x 1,200 x 16 bits @ 60Hz (1,024 x768 when viewed remotely via Oracle
Integrated Lights Out Manager) |
System Processor |
Oracle Integrated Lights Out Manager (Oracle ILOM) provides:
Remote Keyboard, Video, Mouse redirection
Full remote management through command-line, IPMI, and browser interfaces
Remote media capability (DVD, CD, ISO image)
Advanced power management and monitoring
Active Directory, LDAP, RADIUS support
Dual Oracle ILOM flash
Direct virtual media redirection
|
USB |
Rear: Two front accessible USB 2.0 ports
Front: Two rear accessible USB 2.0 ports
Internal: Two internal USB 2.0 ports |
PCI Expansion Slots |
Four PCIe 3.0 slots per server:
PCIe internal slot: dual-port internal SAS HBA
PCIe slot 3: dual-port external SAS HBA
PCIe slot 2: dual-port external SAS HBA
PCIe slot 1: dual-port Infiniband HCA
Optional 10GbE SFP+ external networking connectivity requires replacement of Infiniband HCA
|
Internal Mass Storage |
Disks |
Storage DE2-24C: Sixteen 3.5" 4TB - 7.2K RPM HDDs. (64TB raw, 32TB (double-mirrored) or 21.3TB (triple-mirrored) usable capacity.
Four 2.5" (3.5" bracket) 400GB SAS SSDs. (Per Shelf for frequently accessed data)
Four 2.5" (3.5" bracket) 200GB SAS SDDs. (Per Shelf for database redo logs)
Optional storage expansion with additional storage shelf doubles the storage capacity
Sun Server X5-2: Two 2.5" 600GB - 10K RPM SAS SDDs. (mirrored per server for OS)
|
Power Supplies |
Dual redundant, hot swappable power supplies per server
(Power supply rating output = 600W @ 100-127VAC/200-240VAC)
(AC power: Maximum AC input current at 100VAC and 600W output: 7.2A)
|
Environment |
Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb |
Altitude |
Single, non-rack system:
Operating: up to 3000 m (9,842 ft.), maximum ambient
temperature is derated by 1° C per 300 m (984.25 ft) above 900 m (2,952.76 ft)
Nonoperating: up to 12,000 m (39,370 ft.) |
Regulations
Meets or exceeds the following
requirements: |
Safety |
UL 60950-1 2nd Ed, EN60950-1, IEC60950-1 CB Scheme with all country
differences |
RFI/EMI |
FCC CFR 47 Part 15 Subpart B Class A, EN55022 Class A, EN 61000-3-2,
EN61000-3-3 |
Immunity |
EN55024 |
Certifications |
Safety: cULus, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, KCC, CCC Class A, GOST-R
|
Dimensions and Weight |
Height |
42.6 mm (1.7 in.) per server, 175 mm (6.9in.) per storage shelf |
Width (without mounting ears) |
437 mm (17.2 in.) per server, 483 mm (19 in.) per storage shelf |
Depth |
737 mm (29 in.) per server, 630 mm (24.8 in.) per storage shelf |
Weight |
16.3kg (36 lb.) per server, 37.2kg (82 lbs) per storage shelf |
Rack Mounting |
Oracle Database Appliance Racks |
Racks are as follows:
- One Snap-In Slide Rail Kits is included with each Sun Server X5-2.
One Rackmount Kit is included with the Storage DE2-24C.
|