Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Database Appliance X3-2: Hardware Specifications

Processor
Number Two 8-Core CPU's per Sun Server X3-2
Architecture Type: Intel Xeon 8-Core Processor
CPUs Intel 2.90 GHz 8-Core Xeon E5-2690 (256KB L2, 135W)
Main Memory
Capacities Total DIMM slots: 16 ( per Sun Server X3-2)
DIMM type: DDR3L 1600MHz Registered DIMMs
DIMM size: 16-GB 1600MHz, 1.35V
Maximum capacity: 256GB ( per Sun Server X3-2)
Standard Integrated Interfaces
Network Two 10/100/1000 RJ-45 GbE Ethernet Ports per Sun Server X3-2
Network Management Dedicated 10/100M Base-T Ethernet network management port, In-band, out-of-band and side-band network management access.
Serial Management One RS-232 RJ45 serial port
Video One rear panel high-density HD-15 video port, VGA 2-D embedded graphics controller, support for resolutions of up to 1,280 x 1024 x 16 bits @ 60Hz (1,024 x768 when viewed remotely via Oracle Integraded Lights Out Manager)
System Processor Oracle Integrated Lights Out Manager (Oracle ILOM) provides: Remote Keyboard, Video, Mouse redirection Full remote management through command-line, IPMI, and browser interfaces Remote media capability (DVD, CD, ISO image)
USB Rear: Two front accessible USB 2.0 ports
Front: Two rear accessible USB 2.0 ports
Internal: Two internal USB 2.0 ports
PCI Expansion Slots Three external low profile PCI Express 3.0 slots and One internal slot. Each PCIe slot supports:
  • PCIe slot 1 - x16 mechanical / x16 electrical, dual-port 10GBase-T interconnect for cluster communication
  • PCIe slot 2 - x16 mechanical / x8 electrical, dual-port external SAS-2 HBA
  • PCIe slot 3 - x8 mechanical / x8 electrical, dual-port external SAS-2 HBA
  • PCIe slot 4 - Internal only access, dual-port internal SAS-2 HBA
  • Internal Mass Storage
    Disks Storage DE2-24P:
  • Twenty 2.5" 900GB - 10000 RPM SAS-2 HDDs. (18TB raw, 9TB (double-mirrored) or 6TB (triple-mirrored) usable capacity.)
  • Four 2.5" 200GB SAS-2 SLC SSDs. (Per Shelf for database redo logs. Slots 20-23 only)
  • Sun Server X3-2:
  • Two 2.5" 600GB - 10000 RPM SAS-2 HDDs. (Mirrored for operating system.)
  • Power Supplies
    Dual redundant, hot swappable power supplies
    (Power supply rating output = 600W @ 100-127VAC/200-240VAC)
    (AC power: Maximum AC input current at 100VAC and 600W output: 7.2A)
    Environment
    Temperature Single, non-rack system:
    Operating: 5° C to 35° C (41° F to 95° F)
    Nonoperating: -40° C to 70° C (-40° F to 158° F)
    Humidity Single, non-rack system:
    Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
    Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
    Altitude Single, non-rack system:
    Operating: up to 3000 m (9,842 ft.), maximum ambient temperature is derated by 1° C per 300 m (984.25 ft) above 900 m (2,952.76 ft)
    Nonoperating: up to 12,000 m (39,370 ft.)
    Airflow 290 CFM typical; 400 CFM maximum.
    Regulations
    Meets or exceeds the following requirements:
    Safety UL 60950-1 2nd Ed, EN60950-1, IEC60950-1 CB Scheme with all country differences
    RFI/EMI FCC CFR 47 Part 15 Subpart B Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3
    Immunity EN55024
    Certifications Safety: cULus, CE, BSMI, CCC, GOST-R, S-Mark
    EMC: CE, FCC, VCCI, ICES, C-Tick, KCC, CCC Class A, GOST-R
    Dimensions and Weight
    Height 42.6 mm (1.7 in.) per server, 87.9 mm (3.5in.) per storage shelf
    Width (without mounting ears) 437 mm (17.2 in.) per server, 483 mm (19 in.) per storage shelf
    Depth 737 mm (29 in.) per server, 630 mm (24.8 in.) per storage shelf
    Weight 18kg (40 lb.) per server, 24kg (52.9 lbs) per storage shelf
    Rack Mounting
    Oracle Database Appliance Racks Racks are as follows:
    • One Snap-In Slide Rail Kits is included with each Sun Server X3-2.
      One Rackmount Kit is included with the Storage DE2-24P.

      Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
     Feedback