Processor |
Number |
Two 8-Core CPU's per Sun Server X3-2 |
Architecture |
Type: Intel Xeon 8-Core Processor |
CPUs |
Intel 2.90 GHz 8-Core Xeon E5-2690 (256KB L2, 135W)
|
Main Memory |
Capacities |
Total DIMM slots: 16 ( per Sun Server X3-2)
DIMM type: DDR3L 1600MHz Registered DIMMs
DIMM size: 16-GB 1600MHz, 1.35V
Maximum capacity: 256GB ( per Sun Server X3-2)
|
Standard
Integrated Interfaces |
Network |
Two 10/100/1000 RJ-45 GbE Ethernet Ports per Sun Server X3-2
|
Network Management |
Dedicated 10/100M Base-T Ethernet network management port, In-band, out-of-band and side-band
network management access. |
Serial Management |
One RS-232 RJ45 serial port |
Video |
One rear panel high-density HD-15 video port, VGA 2-D embedded graphics controller, support for
resolutions of up to 1,280 x 1024 x 16 bits @ 60Hz (1,024 x768 when viewed remotely via Oracle
Integraded Lights Out Manager) |
System Processor |
Oracle Integrated Lights Out Manager (Oracle ILOM) provides:
Remote Keyboard, Video, Mouse redirection
Full remote management through command-line, IPMI, and browser interfaces
Remote media capability (DVD, CD, ISO image) |
USB |
Rear: Two front accessible USB 2.0 ports
Front: Two rear accessible USB 2.0 ports
Internal: Two internal USB 2.0 ports |
PCI Expansion Slots |
Three external low profile PCI Express 3.0 slots and One internal slot. Each PCIe slot supports:
PCIe slot 1 - x16 mechanical / x16 electrical, dual-port 10GBase-T interconnect for cluster communication
PCIe slot 2 - x16 mechanical / x8 electrical, dual-port external SAS-2 HBA
PCIe slot 3 - x8 mechanical / x8 electrical, dual-port external SAS-2 HBA
PCIe slot 4 - Internal only access, dual-port internal SAS-2 HBA
|
Internal Mass Storage |
Disks |
Storage DE2-24P: Twenty 2.5" 900GB - 10000 RPM SAS-2 HDDs. (18TB raw, 9TB (double-mirrored) or 6TB (triple-mirrored) usable capacity.)
Four 2.5" 200GB SAS-2 SLC SSDs. (Per Shelf for database redo logs. Slots 20-23 only)
Sun Server X3-2: Two 2.5" 600GB - 10000 RPM SAS-2 HDDs. (Mirrored for operating system.)
|
Power Supplies |
Dual redundant, hot swappable power supplies
(Power supply rating output = 600W @ 100-127VAC/200-240VAC)
(AC power: Maximum AC input current at 100VAC and 600W output: 7.2A)
|
Environment |
Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb |
Altitude |
Single, non-rack system:
Operating: up to 3000 m (9,842 ft.), maximum ambient
temperature is derated by 1° C per 300 m (984.25 ft) above 900 m (2,952.76 ft)
Nonoperating: up to 12,000 m (39,370 ft.) |
Airflow |
290 CFM typical; 400 CFM maximum. |
Regulations
Meets or exceeds the following
requirements: |
Safety |
UL 60950-1 2nd Ed, EN60950-1, IEC60950-1 CB Scheme with all country
differences |
RFI/EMI |
FCC CFR 47 Part 15 Subpart B Class A, EN55022 Class A, EN 61000-3-2,
EN61000-3-3 |
Immunity |
EN55024 |
Certifications |
Safety: cULus, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, KCC, CCC Class A, GOST-R
|
Dimensions and Weight |
Height |
42.6 mm (1.7 in.) per server, 87.9 mm (3.5in.) per storage shelf |
Width (without mounting ears) |
437 mm (17.2 in.) per server, 483 mm (19 in.) per storage shelf |
Depth |
737 mm (29 in.) per server, 630 mm (24.8 in.) per storage shelf |
Weight |
18kg (40 lb.) per server, 24kg (52.9 lbs) per storage shelf |
Rack Mounting |
Oracle Database Appliance Racks |
Racks are as follows:
- One Snap-In Slide Rail Kits is included with each Sun Server X3-2.
One Rackmount Kit is included with the Storage DE2-24P.
|