| Processor |
| Number |
Two 6-Core CPU's per System Controller |
| Architecture |
Type: Intel Xeon 6-Core Processor |
| CPUs |
Intel 3.06 GHz 6-Core Xeon E5675 (12MB L2, 95W) |
| Main Memory |
| Capacities |
Total DIMM slots: 12 ( per System Controller)
DIMM type: DDR3 1333MHz Registered DIMMs
DIMM size: 8-GB 1333MHz, 1.35V
Maximum capacity: 96GB ( per System Controller)
|
| Standard Integrated Interfaces
|
| Network |
Two 10/100/1000 RJ-45 GbE Ethernet Ports on each System Controller
|
| Network Management |
One dedicated 10/100 RJ-4 GbE port dedicated to the Service Processor
(SP) on each System Controller |
| Serial Management |
One RS-232 RJ45 serial port on each System Controller |
| Video |
One rear panel high-density HD-15 video port on each system controller |
| System Controller |
Two system controllers (SCs) per chassis. Each SC operates independently
from the other. The lower system controller is SC 0; the upper system controller
is SC 1 |
| USB |
Rear: Two USB 2.0 ports (for each system controller)
Internal: One USB 2.0 port (for each system controller) |
| PCI Expansion Slots |
Three external low profile PCI Express Gen-2 slots (x8) for each system
controller. Each PCIe slot supports:
PCIe slot 2 - Dual-port SAS-2 host bus adapter (HBA) as part of the
base configuration
PCIe slot 1 - Quad-port 1Gb Ethernet NIC
PCIe slot 0 - Dual-port 10Gb Ethernet NIC
One internal low profile PCI Express Gen-2 slot (x8). Dual-port SAS-2 HBA
as part of the base configuration. |
| Internal Mass Storage |
| Disks |
SAS: Up to twenty 3.5" 600GB - 15000 RPM SAS HDDs in slots 0-19.
SSD: Up to four 3.5" 73GB SAS Solid State Disks in slots 20-23.
NOTE: The following storage configurations are supported for each
System Controller:
Two rear accessed 2.5" 500GB - 7200 RPM SATA HDDs (reserved for operating
system storage and system booting).
One internal 4 GB USB Memory Stick
|
| Power Supplies |
Dual redundant, hot swappable power supplies
(Power supply rating output = 1200W)
(1100W @ 100-120 VAC; 1200W at 200-240 VAC, 50-60 Hz)
(UL Maximum AC input = 1200W x 1.33 efficiency = 1596W)
|
| Service Processors |
Each System Controller has a Service Processor with the following
features:
Includes the Baseboard Management Controller (BMC), which supports
the IPMI feature set.
Supports KVMS over IP.
Includes a Serial port.
Supports Ethernet access to the Service Processor through a dedicated
10/100BaseT management port.
|
| Environment |
| Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
| Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27° C
(80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38°
C (100.4° F) max wet bulb |
| Altitude |
Single, non-rack system:
Operating: up to 3048 m (10,000 ft.), maximum ambient temperature
is derated by 1° C per 300 m (984.25 ft) above 900 m (2,952.76 ft)
Nonoperating: up to 12,000 m (39,370 ft.) |
| Airflow |
130 CFM typical; 250 CFM maximum. |
Regulations
Meets or exceeds the following requirements: |
| Safety |
UL 60950-1 2nd Ed, EN60950-1:2006 2nd Ed, CB Scheme with all country differences |
| RFI/EMI |
FCC CFR 47 Part 15 Subpart B Class A, EN55022:2006+A1:2007 Class A, EN
61000-3-2, EN61000-3-3, EN 300-386 |
| Immunity |
EN55024, EN300-386 |
| Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
|
| Dimensions and Weight |
| Height |
175.1 mm (6.9 in.) |
| Width (without mounting ears) |
437 mm (17.2 in.) |
| Width (with mounting ears) |
482.6 mm (19 in.) |
| Depth (to back of fan modules) |
762 mm (30 in.) |
| Depth (to fan module handles and latches) |
782 mm (30.8 in.) |
| Weight |
72.6 kg (160 lb.) |
| Rack Mounting |
| Rack structure |
- Four-post Racks are supported (mounting at both front and rear)
- Two-post Racks are not compatible
|
| Rack horizontal opening and unit vertical pitch |
Rack horizontal opening and unit vertical pitch must conform to ANSI/EIA
310-D-1992 or IEC 60927 standards. |
| Distance between front and rear mounting planes |
Minimum 660.4mm and maximum 876.3mm (26 inches to 34.5 inches). |
| Clearance depth in front of front mounting plane |
Distance to the front cabinet door must be at least 25.4 mm (1.0"). |
| Clearance depth behind front mounting plane |
Distance to the rear cabinet door must be at least 700 mm (27.5"). |
| Clearance width between front and rear mounting planes |
Distance between structural supports and cable troughs must be at least
456 mm (18"). |