Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Advanced Support Gateway Server X4-2: Hardware Specifications

Processor
Number Two
Architecture Type: Intel Xeon E5-2600 v2 family
CPUs Intel 2.5 GHz 4-Core Xeon E5-2609 v2 (80W)
Cache L1: 32KB Instruction and 32KB data L1 cache per core
L2: 256KB shared data and instruction L2 cache per core
L3: Up to 20MB shared inclusive L3 cache per processor
Main Memory
Capacities Total DIMM slots: 16
DIMM type: DDR3 1600MHz Registered DIMMs
DIMM size: 8GB 1600MHz
Maximum capacity: 128GB
Standard Integrated Interfaces
Network Supports Four 100/1000/10000 Base-T Ethernet Ports (100 at full-duplex only)
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated RJ45 port
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: Two USB 2.0 ports
PCI Expansion Slots

Four low profile PCI Express 3.0 slots;
Slot 1: x16 mechanical / x16 electrical
Slot 2: x16 mechanical / x8 electrical
Slot 3: x8 mechanical / x8 electrical
Slot 4: Internal only access, dedicated to SAS controller for internal storage.

Internal Mass Storage
Disks 8-Disk configuration: 2.5in 600GB SAS-2 SSD
Uses one of two supported internal HBAs for internal storage. The HBA is to be installed in PCI Express Slot 4 (internal access only, under PCI Express Slot 3)
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 600W)
Environment
Voltage 100 to 127 / 200 to 240 VAC (90 to 132/180 to 264 VAC ranges)
Input Current 7.2 A @ 100 VAC (720 VA) Max
AC power 50-60 Hz (47 to 63 Hz range)
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Maximum ambient operating temperature is derated by 1 degree C per 300 meters of elevation beyond 900 meters, up to a maximum altitude of 3,000 meters of elevation.)
Humidity Operating: 10% to 90% relative humidity noncondensing, short term -5 ° C to 55° C (25° F to 113° F) ;
5% to 90% noncondensing, but not to exceed 0.024 kg of water per kg of dry air (0.053 lbs water / 2.205 lbs dry air)
Nonoperating: up to 93% relative humidity noncondensing, 37.7° C (100.4° F) max wet bulb
Altitude Operating: up to 3000 m (9,840 ft.) at 35° C (95° F)
Nonoperating: Maximum 12,000 m (39,370 ft)
Note - In China markets, regulations may limit installations to a maximum altitude of 6,562 feet (2,000 meters).
Acoustic 7.91 Bels A weighted operating; 5.28 Bels A weighted idling
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, 2nd Edition, 2007-03-27 ; EN60950-1:2006 +A11:2009 +A1:2010 +A12:2011 ; IEC60950-1:2005 +A1:2009CB Scheme with all country deviations ; CNS14336-1 ; GB4943
EMI EN55022:2006 +A1:2007/CISPR22:2008 Class A ; 47 CFR 15B Class A ; ICES-003 Class A ; VCCI Class A ; AS/NZ 3548 Class A ; CNS 13438 Class A ; GB9254 Class A ; EN61000-3-2 ; GB17625.1 ; EN61000-3-3
Immunity EN55024:2010 ; IEC 61000-4-2 Electrostatic discharge ; IEC 61000-4-3 RF E-field immunity ; IEC 61000-4-4 Electrical Fast Transient/Burst ; IEC 61000-4-5 Surge ; IEC 61000-4-6 RF-Conducted immunity ; IEC 61000-4-8 Power frequency magnetic field immunity ; IEC 61000-4-11 Voltage dips, short interruptions
Ergonomics EK1-1TB-2000
Dimensions and Weight
Height 42.6 mm (1.7 in)
Width With Bezel: 482.4 mm (18.9 in)
Server Chassis: 436.5 mm (17.185 in)
Depth 737 mm (29 in) Max
Weight 18.0 kg (40 lbs)
Clearance and Service Access
Front
Rear
123.2 cm (48.5 in)
91 cm (36 in)
Rack Mounting
Sun Server X4-2 Server Racks Racks are as follows:
  • Sun Rack II 1042
  • Sun Rack II 1242

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.