Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Advanced Support Gateway Server X3-2: Hardware Specifications

Processor
Number Two Quad-Core
Architecture Type: Intel Xeon E5-2600 family
CPUs Intel 2.4GHz Quad-Core Xeon E5-2609 (10MB, 80W)
Main Memory
Capacities DIMM type: DDR3 1600MHz Registered DIMMs
DIMM size: 8GB 1600MHz
Capacity: 48GB (6 × 8GB)
Standard Integrated Interfaces
Network Supports Four 100/1000/10000 Base-T Ethernet Ports (100 at full-duplex only)
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated RJ45 port
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: Two USB 2.0 ports
PCI Expansion Slots

Four low profile PCI Express 3.0 slots;
Slot 1: x16 mechanical / x16 electrical
Slot 2: x16 mechanical / x8 electrical
Slot 3: x8 mechanical / x8 electrical
Slot 4: Internal only access, dedicated to SAS controller for internal storage.

Internal Mass Storage
Disks 3 × 2.5in 600GB SAS-2
Uses one internal HBA for internal storage. The HBA is to be installed in PCI Express Slot 4 (internal access only, under PSI Express Slot 3)
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 600W)
Environment
Voltage 100 to 127 / 200 to 240 VAC (90 to 132/180 to 264 VAC ranges)
Input Current 7.2 A @ 100 VAC (720 VA) Max
AC power 50-60 Hz (47 to 63 Hz range)
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Maximum ambient operating temperature is derated by 1 degree C per 300 meters of elevation beyond 900 meters, up to a maximum altitude of 3,000 meters of elevation.)
Humidity Operating: 10% to 90% relative humidity noncondensing, short term -5 ° C to 55° C (25° F to 113° F) ;
5% to 90% noncondensing, but not to exceed 0.024 kg of water per kg of dry air (0.053 lbs water / 2.205 lbs dry air)
Nonoperating: up to 93% relative humidity noncondensing, 37.7° C (100.4° F) max wet bulb
Altitude Operating: up to 3000 m (9,840 ft.) at 35° C (95° F)
Nonoperating: Maximum 12,000 m (39,370 ft)
Acoustic 7.91 Bels A weighted operating; 5.28 Bels A weighted idling
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, 2nd Edition, 2007-03-27 ; EN60950-1:2006 +A11:2009 +A1:2010 +A12:2011 ; IEC60950-1:2005 +A1:2009CB Scheme with all country deviations ; CNS14336-1 ; GB4943
EMI EN55022:2006 +A1:2007/CISPR22:2008 Class A ; 47 CFR 15B Class A ; ICES-003 Class A ; VCCI Class A ; AS/NZ 3548 Class A ; CNS 13438 Class A ; KSC 5858 Class A ; GB9254 Class A ; EN61000-3-2 ; GB17625.1 ; EN61000-3-3
Immunity EN55024:2010 ; IEC 61000-4-2 Electrostatic discharge ; IEC 61000-4-3 RF E-field immunity ; IEC 61000-4-4 Electrical Fast Transient/Burst ; IEC 61000-4-5 Surge ; IEC 61000-4-6 RF-Conducted immunity ; IEC 61000-4-8 Power frequency magnetic field immunity ; IEC 61000-4-11 Voltage dips, short interruptions
Ergonomics EK1-1TB-2000
Dimensions and Weight
Height 42.6 mm (1.7 in)
Width With Bezel: 482.4 mm (18.9 in)
Server Chassis: 436.5 mm (17.185 in)
Depth 737 mm (29 in) Max
Weight 24.3 kg (53.4 lbs)
Clearance and Service Access
Front
Rear
91 cm (36 in)
91 cm (36 in)

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.