Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra Server X5-2 for Communications: Hardware Specifications

Processor
Number 2 Processors
Architecture Type: Intel Xeon E5-2600 v3 Processor Series
CPUs Intel Xeon 2.3GHz 18-Core E5-2699 v3, 145W (capped at 120W)
Cache Level 1: 64 KB cache per core including 32 KB L1 data + 32 KB L1 instruction
Level 2: 256 KB shared data and instruction L2 cache per core
Level 3: Up to 8 MB shared inclusive L3 cache per processor
Main Memory
Capacities
  • DIMM Slots: 24
  • DIMM Size and Type: 16 GB DDR4-2133
  • Minimum Memory Capacity: 32GB
  • Maximum Memory Capacity: Varies by configuration from 64GB to 384GB
  • DIMMs per memory channel: 3
  • Advanced ECC: Yes
Standard I/O
Network
  • Four onboard auto-sensing 100/1000/10,000 BASE-T Ethernet (GbE) ports (RJ-45 connector)
Network Management One 10/100/1000 Base-T Network Management (NET MGT/RJ-45 connector) port
Serial Management One serial console (SER MGT/RJ-45 connector) port
USB Rear: 2 USB 2.0 (capable of 3.0) Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports
Graphics
  • One VGA 2D embedded graphics controller with DB-15 connector
  • Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
I/O Expansion Six low profile PCIe 3.0 slots:
  • PCI-E slot 1: x16 (Internal SAS HBA occupies slot 1)
  • PCI-E slot 2: x8
  • PCI-E slot 3: x8
  • PCI-E slot 4: x8
  • PCI-E slot 5: x16
  • PCI-E slot 6: x8
Internal Mass Storage
Disks and DVD
  • Eight-disk chassis: eight 2.5-inch SAS-3 front accessible, hot-swappable disk bays with no DVD-RW
  • Internal 8GB USB 2.0 Flash Drive
  • Supported Disks: 1.2TB - 10000 RPM, 600GB - 10000 RPM, and 400GB Solid State SAS Drive
Power Supplies
  • Two 1,200W (1+1 Redundancy) AC and DC
Environment
Power Consumption Online power calculator
AC power Operating voltage: 100 to 240 VAC
DC power Operating voltage: -40 to -72 VDC
Temperature Operating: 5° C to 45° C (41° F to 113° F); short term: -5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 85% relative humidity noncondensing, but not to exceed 0.024 Kg water/Kg dry air (0.053 lb. water/2.205 lb. dry air)
Nonoperating: 93% noncondensing, 40° C (104° F)
Short-term: 5% - 90% relative humidity noncondensing, but not to exceed 0.024 Kg water/Kg dry air (0.053 lb. water/2.205 lb. dry air)
Altitude Operating: meets NEBS 4,000 m (13,123 ft.) requirement
Nonoperating: up to 12,000 m (39,370 ft)
Acoustic Noise Operating/idling less than 7.2 dB @ 23° C (LwAd: 1 B=10 dB)
Regulations
Meets or exceeds the following requirements:
ETSI EN 300019-2-1,2,3, Class 1.2, 2.3, 3.1E (except condensing humidity and rain)
NEBS NEBS Level 3 certified by Telecordia
Seismic GR-63-CORE requirements for earthquake Zone 4
Safety UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences
Emissions FCC CFR 47 Part 15, ICES-003, EN55024, EN61000-3-2 and EN61000-3-3, EN300-386
Immunity EM55024
Certifications
  • North America Safety (NRTL)
  • European Union (EU)
  • International CB Scheme
  • BIS (India)
  • BSMI (Taiwan)
  • RCM (Australia)
  • CCC (PRC)
  • MSIP (Korea)
  • VCCI (Japan)
  • EAC (Russia)
European Union Directives
  • 2006/95/EC Low Voltage Directive
  • 2004/108/EC EMC Directive
  • 2011/65/EU RoHS Directive
  • 2012/19/EU WEEE Directive
Dimensions and Weights
Height 87.1mm (3.43 in).
Width (including bezel): 445mm (17.52 in) and without bezel 425.4 mm (16.75 in.).
Depth 640.0 mm (25.2 in.) with power supplies, or 609.45 mm (24 in.) without power supplies.
Weight 17.5 kg (38.5 lbs) fully populated.
Rack Mounting
Netra Server X5-2 Racks
  • Rack Units: 2
  • 19" 4-Post Rackmount Brackets
  • New Netra Chassis is 24" deep, 2U high
  • Sun Rack 1242 support
  • Sun Rack 1042 support

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback