Processor |
Number |
2 Processors |
Architecture |
Type: Intel Xeon E5-2600 v3 Processor Series |
CPUs |
Intel Xeon 2.3GHz 18-Core E5-2699 v3, 145W (capped at 120W)
Intel Xeon 2.4GHz 8-Core E5-2630 v3, 85W |
Cache |
Level 1: 64 KB cache per core including 32 KB L1 data + 32 KB L1 instruction
Level 2: 256 KB shared data and instruction L2 cache per core
Level 3: Up to 8 MB shared inclusive L3 cache per processor
|
Main Memory |
Capacities |
- DIMM Slots: 24
- DIMM Size and Type: 32 GB LR DDR4-2133 or 16 GB DDR4-2133
- Minimum Memory Capacity: 64GB using 32GB DIMMs or 32GB using 16GB DIMMs
- Maximum Memory Capacity: 768 GB using 32GB DIMMs or 384 GB using 16GB DIMMs
- DIMMs per memory channel: 3
- Advanced ECC: Yes
|
Standard I/O |
Network |
- Four onboard auto-sensing 100/1000/10,000 BASE-T Ethernet (GbE) ports (RJ-45 connector)
|
Network Management |
One 10/100/1000 Base-T Network Management (NET MGT/RJ-45 connector) port |
Serial Management |
One serial console (SER MGT/RJ-45 connector) port |
USB |
Rear: 2 USB 2.0 (capable of 3.0) Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports |
Graphics |
- One VGA 2D embedded graphics controller with DB-15 connector
- Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
|
I/O Expansion |
Six low profile PCIe 3.0 slots:
- PCI-E slot 1: x16
- PCI-E slot 2: x8
- PCI-E slot 3: x8
- PCI-E slot 4: x8
- PCI-E slot 5: x16
- PCI-E slot 6: x8 (optional full RAID support HBA occupies slot 6)
|
Internal
Mass Storage |
Disks and DVD |
Two Disk Backplanes configurations
- Eight-disk chassis: eight 2.5-inch SAS-3 front accessible, hot-swappable disk bays with no DVD-RW
- Six-disk chassis: six 2.5-inch SAS-3 front accessible, hot-swappable disk bays and DVD-RW
- Internal 8GB USB 2.0 Flash Drive
- Supported Disks: 1.2TB - 10000 RPM, 600GB - 10000 RPM, 400GB and 800GB Solid State SAS Drives
- Front Bays: Support 10,000 RPM
- RAID:
- The motherboard LSI3008 SAS3 controller supports IT (Initiator/Target) mode
- The motherboard LSI3008 SAS3 controller does not support IR (Integrated RAID) or RAID 0/1
- Optional full RAID support requires RAID Disk Controller installed in PCIe slot 6
- The RAID Disk Controller includes a SuperCap module that acts as a battery backup for cache
|
Power Supplies |
- Two 1,200W (1+1 Redundancy) AC and DC
|
Environment |
Power Consumption |
Online power calculator |
AC power |
Operating voltage: 100 to 240 VAC
|
DC power |
Operating voltage: -40 to -72 VDC
|
Temperature |
Operating: 5° C to 45° C (41° F to 113° F); short term: -5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Operating: 5% to 85% relative humidity noncondensing, but not to exceed 0.024 Kg water/Kg dry air (0.053 lb. water/2.205 lb. dry air)
Nonoperating: 93% noncondensing, 40° C (104° F)
Short-term: 5% - 90% relative humidity noncondensing, but not to exceed 0.024 Kg water/Kg dry air (0.053 lb. water/2.205 lb. dry air)
|
Altitude |
Operating: meets NEBS 4,000 m (13,123 ft.) requirement
Nonoperating: up to 12,000 m (39,370 ft)
|
Acoustic Noise |
Operating/idling less than 7.2 dB @ 23° C (LwAd: 1 B=10 dB)
|
Regulations
Meets or exceeds the following requirements: |
ETSI |
EN 300019-2-1,2,3, Class 1.2, 2.3, 3.1E (except condensing humidity and rain)
|
NEBS |
NEBS Level 3 certified by Telecordia
|
Seismic |
GR-63-CORE requirements for earthquake Zone 4
|
Safety |
UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country
differences |
Emissions |
FCC CFR 47 Part 15, ICES-003, EN55024, EN61000-3-2 and EN61000-3-3, EN300-386
|
Immunity |
EM55024 |
Certifications |
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- CCC (PRC)
- MSIP (Korea)
- VCCI (Japan)
- EAC (Russia)
|
European Union Directives |
- 2006/95/EC Low Voltage Directive
- 2004/108/EC EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions and Weights |
Height |
87.1mm (3.43 in). |
Width |
(including bezel): 445mm (17.52 in) and without bezel 425.4 mm (16.75 in.). |
Depth |
640.0 mm (25.2 in.) with power supplies, or 609.45 mm (24 in.) without power supplies. |
Weight |
17.5 kg (38.5 lbs) fully populated. |
Rack
Mounting |
Netra Server X5-2 Racks
|
- Rack Units: 2
- 19" 4-Post Rackmount Brackets
- New Netra Chassis is 24" deep, 2U high
- Sun Rack 1242 support
- Sun Rack 1042 support
|