Interfaces |
InfiniBand
Up to 38 4x InfiniBand ports
- 24 4x InfiniBand MPO PMT ports
- 4 12x InfiniBand MPO PMT ports
- 2 Configurable Ports
- 4x InfiniBand or
- 40GbE Gateway MPO PMT
|
Ethernet
- 24 1GbE RJ45 ports
- 2 SFP+ Uplink Ports
- 1000Base-T
- 10Gb Short Range or 10Gb Long Range
- 1 Serial Management Port
|
|
AC Power |
Voltage:100 VAC to 240 VAC single phase, 47 to 63 Hz
Current (per input): 5.4A maximum per input at 100 VAC
Current (total): 5.6A maximum total for all inputes at 100 VAC
Power: 550W (Total input power is apporximately equally divided among the operating power supplies.)
|
Temperature |
Operating: 5° (41° F) -
35° C (95° F) |
Relative Humidity |
Operating: 5%
to 85% (non-condensing), 27° C (80° F) maximum wet bulb |
Elevation |
Operating: Maximum 3000 meters
at 40° C (9840 feet at 104° F) |
|
Height |
44.5 mm (1.75 in) |
Width |
445 mm (17.52 in) |
Depth |
609.6 mm (24 in)
|
Weight (maximum) |
11.4 kg (23 lb)
|
Rack Units |
1
|
|
4-post EIA Rack |
Air flows from the front (fan end)
of the switch to the rear (connector end) of the switch. Air flows through the power supplies
from the sides of the switch to out the front.
The switch has a shorter form factor than Oracle rackmounted computing products. There is a gap
between the rack front door and the switch front panel. To aid in proper airflow management and
minimize air recirculation within the rack, install the air duct assembly at the front of the switch. |