Processor
Number Up to Two 12-Core (One per CPU/Memory Unit)
Architecture Type: SPARC64 12-Core Processor
CPUs M12-2S SPARC 4.25GHz 12-Core (64KB data, 64KB per core L1, 512KB I$ per core L2, 32MB L3$ per CPU)
One CPU on the Upper CPU/Memory Unit (CMUUQN)
One CPU on the Lower CPU/Memory Unit (CMULQN)
Main Memory
Capacities Total DIMM slots: 16 per CPU socket (32 total DIMM slots x 2 CPU sockets)
DIMM type: DDR4 2400MHz Registered DIMMs
DIMM size: 8GB, 16GB, 32GB and 64GB
Maximum capacity: 2TB (when configured with 64GB DIMMs and 2 CPU sockets)
Standard Integrated Interfaces
Network Four 10GbE Ethernet Ports
Service Processor Two 1000 Base-T RJ45 network ports
One RJ45 serial management port
Two USB Maintenance ports
SAS Two SAS-2 controllers providing hardware RAID 0, 1 and 1E/10 (ZFS file system provides higher level RAID)
USB Front: One USB 2.0 port
Rear: One USB 3.0 port
PCI Expansion Slots Eight low profile PCI Express 3.0 slots (8 x8 electrical/mechanical)
Internal Mass Storage
Disks Up to eight front accessible disk bays with 2.5" SAS disks or eight solid-state drives (SSDs)
Drive Type
Density
Speed
Form Factor
SAS
600 GB
10,000 RPM
2.5"
SAS
900 GB
10,000 RPM
2.5"
SAS-2 Solid State Drive
400 GB
NA
2.5"
XB-Box (Crossbar box) (XBUQB_A)
Number of Building Block Modules that can be connected XB-Box x 2 (4Ux2) = up to 32 CPU's or sockets
Note: Used to connect BB Modules for system configurations larger than 16 CPU's or sockets (4BBs)
Service Processor Redundant with XB-Box configuration.
XSCF in XB-Box becomes Master.
Two XB-Boxes provide redundancy (Master-Slave roles).
Power Supplies
Four hot-swappable AC 1,800 W redundant (2 + 2) power supplies
Voltage 200 to 240 VAC, frequency 50Hz/60Hz
Maximum operating input current at 200 V AC: 17.2 A
Maximum operating input power at 200 V AC: 2,906 W
Environment
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F) 0 to 500 m
Nonoperating: -25° C to 60° C (-13° F to 140° F)(packed)
Nonoperating: 0 to 50° C (32° F to 122° F)(unpacked)
Humidity Single, non-rack system:
Operating: 20% to 80% relative humidity noncondensing
Nonoperating: 8% to 80% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA 60950-1, EN60950-1, IEC 60950-1 CB Scheme with all country differences
EMC Emissions: FCC CFR 47 Part 15, ICES-003, EN 55032, KN32, VCCI V3/2015-04, EN61000-3-2, EN 61000-3-3, JIS C 61000-3-2
Immunity EN55024, KN35
Certifications North America Saftey (NRTL), European Union (EU), International CB Scheme,
BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan), EAC (Eurasia)
Dimensions and Weight
Height 175 mm (6.89 in.); 4U
Width 440 mm (17.32in.)
Depth 800 mm (31.5 in.)
Weight 60 kg (127.87 lb.)
Rack Mounting
Fujitsu M12-2 Server Rack Rack is as follows:
  • Fujitsu Expansion Rack
  • Sun Rack II 1042
  • Sun Rack II 1242
  • Sun Rack 900-38
  • Sun Rack 1000-38
  • Sun Rack 1000-42
  • Sun Rack 900-36N

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.