Processor |
Number |
Up to Two 12-Core (One per CPU/Memory Unit) |
Architecture |
Type: SPARC64 12-Core Processor |
CPUs |
SPARC 3.9GHz 12-Core (64KB data, 64KB per core L1, 512KB I$ per core L2, 32MB L3$ per CPU)
|
Main Memory |
Capacities |
Total DIMM slots: 16 per CPU socket (32 total DIMM slots x 2 CPU sockets)
DIMM type: DDR4 2400MHz Registered DIMMs
DIMM size: 8GB, 16GB, 32GB and 64GB
Maximum capacity: 2TB (when configured with 64GB DIMMs and 2 CPU sockets)
|
Standard
Integrated Interfaces |
Network |
Four 10GbE Ethernet Ports
|
Service Processor |
Two 1000 Base-T RJ45 network ports
One RJ45 serial management port
Two USB Maintenance ports
|
SAS |
Two SAS-2 controllers providing hardware RAID 0, 1 and 1E/10 (ZFS file system provides higher level RAID) |
USB |
Front: One USB 2.0 port
Rear: One USB 3.0 port |
PCI Expansion Slots |
Eleven low profile PCI Express 3.0 slots
(11 x8 electrical/mechanical) |
Internal Mass Storage |
Disks |
Up to eight front accessible disk bays with 2.5" SAS disks or eight solid-state drives (SSDs)
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS
|
600 GB
|
10,000 RPM
|
2.5"
|
SAS
|
900 GB
|
10,000 RPM
|
2.5"
|
SAS-2 Solid State Drive
|
400 GB
|
NA
|
2.5"
|
|
Power Supplies |
Four hot-swappable AC 1,800 W redundant (2 + 2) power supplies
Voltage 200 to 240 VAC, frequency 50Hz/60Hz
Maximum operating input current at 200 V AC: 17.2 A
Maximum operating input power at 200 V AC: 2,906 W
|
Environment |
Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F) 0 to 500 m
Nonoperating: -25° C to 60° C (-13° F to 140° F)(packed)
Nonoperating: 0 to 50° C (32° F to 122° F)(unpacked)
|
Humidity |
Single, non-rack system:
Operating: 20% to 80% relative humidity noncondensing
Nonoperating: 8% to 80% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient
temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.) |
Regulations
Meets or exceeds the following
requirements: |
Safety |
UL/CSA 60950-1, EN60950-1, IEC 60950-1 CB Scheme with all country differences |
EMC |
Emissions: FCC CFR 47 Part 15, ICES-003, EN 55032, KN32, VCCI V3/2015-04,
EN61000-3-2, EN 61000-3-3, JIS C 61000-3-2 |
Immunity |
EN55024, KN35 |
Certifications |
North America Saftey (NRTL), European Union (EU), International CB Scheme,
BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan), EAC (Eurasia)
|
Dimensions and Weight |
Height |
175 mm (6.89 in.); 4U |
Width |
440 mm (17.32in.) |
Depth |
800 mm (31.5 in.) |
Weight |
60 kg (127.87 lb.) |
Rack Mounting |
Fujitsu M12-2 Server Rack |
Rack is as follows:
- Fujitsu Expansion Rack
- Sun Rack II 1042
- Sun Rack II 1242
- Sun Rack 900-38
- Sun Rack 1000-38
- Sun Rack 1000-42
- Sun Rack 900-36N
|