Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Fujitsu M12-1 Server: Hardware Specifications

Processor
Number One 6-Core (48 threads)
Architecture Type: SPARC64 XII 6-Core Processor
CPUs M12-1 SPARC 3.2GHz 6-Core (16MB L3 cache)
Main Memory
Capacities Total DIMM slots: 16
DIMM type: DDR4 2400MHz Registered DIMMs
DIMM size: 8GB, 16GB, 32Gb or 64GB
Maximum capacity: 1TB (when configured with 64GB DIMMs)
Standard Integrated Interfaces
Network Four 10GbE Ethernet Ports
Service Processor One dedicated TIA/EIA-232-F asynchronous RJ45 port
One USB Maintenance port
Two 1GbE Ethernet Ports
SAS One 6Gbps channel SAS-2 interface
USB Front: One USB 2.0 ports
Rear: One USB 2.0 ports
PCI Expansion Slots Three low profile PCI Express 3.0 slots (3 x8 electrical/mechanical)
Internal Mass Storage
Disks Up to eight front accessible disk bays with 2.5" SAS disks or eight solid-state drives (SSDs)
Drive Type
Density
Speed
Form Factor
SAS
900 GB
10,000 RPM
2.5"
SAS
600 GB
10,000 RPM
2.5"
SAS Solid State Drive
400 GB
NA
2.5"
Power Supplies
Dual redundant, hot swappable power supplies
Maximum AC input = Max 785W (at 100-120VAC), Max 774W (at 200-240VAC)
Environment
AC power 100-120 / 200-240 VAC (1-phase)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -25° C to 60° C (-13° F to 140° F)(unpacked)
Humidity Single, non-rack system:
Operating: 20% to 80% relative humidity noncondensing
Nonoperating: 20% to 80% relative humidity noncondensing (unpacked)
Altitude Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Regulations
Meets or exceeds the following requirements:
Safety UL 60950-1 2nd Ed, EN60950-1:2006 2nd Ed, CB Scheme with all country differences
RFI/EMI EN55032:2015Class A, EN 61000-3-2:2014, EN61000-3-3:2013, FCC Part-15 Supart B: 2017 Class A
Immunity EN55024:2010, GOST CISPR 24-2013
Dimensions and Weight
Height 42.5 mm (1.67 in.)
Width 431 mm (16.97 in.)
Depth 721 mm (28.39 in.)
Weight 18 kg (39.68 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
Rack Mounting
Fujitsu M12-1 Server Rack Rack is as follows:
  • Fujitsu Expansion Rack
  • Sun Rack II 1042
  • Sun Rack II 1242

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback