Processor |
Number |
4 CPUs, each 15-Core |
Architecture |
Type: Intel Xeon E7-8895 Processor Series |
CPUs |
Intel 2.80GHz 15-Core Xeon E7-8895 v2, 155W
|
Cache memory |
256KB unified (data and instruction) Level 2 cache
Up to 37.5MB shared last Level 3 cache |
Main
Memory |
Capacities |
DIMM slots: 64 DIMM slots, 16 DIMMs per CPU
DIMM type: Registered DDR3L-1600 DIMMs
DIMM size: 32GB
Maximum capacity: 2TB |
Standard
Integrated Interfaces |
Network |
Four 10 GbE on-board Ethernet copper ports |
Network Management |
One dedicated 10/100/1000 Base-T Ethernet copper management port |
Serial Management |
One RS-232 RJ45 serial port |
USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
Internal: 1 USB 2.0 Port |
PCI Express |
11 PCI Express 3.0 Slots
- 9 slots are x8 PCI-E slots
- 2 slots are x16 PCI-E slots
Note: Slots 2 is designated for the storage controller HBA.
|
Video |
One Rear and One Front HD15 VGA port |
Graphics controller |
VGA 2D graphics controller embedded.
Support remote console at a resolution up to 1600x1200x16bits@60Hz
(1024x678 when viewed remotely via ILOM RKVMS)
|
Internal
Mass Storage |
Disks |
Up to 6 hot-swappable disks
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS
|
1.2TB
|
10,000 RPM
|
2.5"
|
|
Power
Supplies |
Dual redundant, hot swappable power supplies
2000W Capacity (From 200 Volts to 240 Volts)
|
Environment |
AC power |
100-127 VAC for 2 CPU's
200-240 VAC for 2 or 4 CPU's
50/60 Hz Nominal frequencies |
Maximum Input Current |
12A @ 100VAC / 12A @ 200VAC |
Maximum Power Consumption |
1467W |
Maximum Heat Output |
5005 BTU/hr |
Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 68° C (-40° F to 154°F) |
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing
Nonoperating: up to 93% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: Up to 3048 m (10,000 ft.), maximum operating temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.) |
Acoustic Noise Emissions |
LwAd (1B= 10dB) at max ambient: 8.9 B (idle and operating room temperature)
LpAm bystander at max ambient: 75 dBA |
Regulations
Meets or exceeds the following requirements: |
Safety |
IEC 60950, UL/CSA60950-1, EN60950-1, IEC60950-1 (CB scheme with all country differences), North America
(NRTL), European Union (EU), International CB Scheme, 2006/95/EC (73/23/EEC) Low Voltage Directive |
EMC |
FCC CFR 47 Part 15B Class A, EN55022 Class A, CNS-13438 Class A (Taiwan), Title 47, Part 15, Subpart B Class A
(Unites States), ICES-003 (A) (Japan), KN 22 RRL Public Notice 2009-9 (Dec 21, 2009)/td>
|
Immunity |
EN 55024 (Immunity), EN61000-3-2, EN61000-3-3 |
Certifications |
Safety: UL/cUL, UL DEMKO, CCC, CE, BSMI, GOST-R, S-Mark
Regulatory: CE, FCC, EAC, C-Tick, VCCI, BSMI, KCC,ICES-003(A),
NMB-3(A), WEE symbol, China RoHS symbol |
Dimensions
and Weight |
Height |
129.9 mm (5.1 in.) |
Width |
436.5 mm (17.2 in.) |
Depth |
732 mm (28.8 in.) |
Weight |
Maximum: 40 kg (88 lb.) |
Rack
Mounting |
Exalytics In-Memory Machine X4-4 Racks
( Using the Tooless Slide Rail Rackmount Kit PN#371-4791 ) |
Racks are as follows:
- Sun Rack 1242