Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Exalytics In-Memory Machine X4-4: Hardware Specifications

Processor
Number 4 CPUs, each 15-Core
Architecture Type: Intel Xeon E7-8895 Processor Series
CPUs Intel 2.80GHz 15-Core Xeon E7-8895 v2, 155W
Cache memory 256KB unified (data and instruction) Level 2 cache
Up to 37.5MB shared last Level 3 cache
Main Memory
Capacities DIMM slots: 64 DIMM slots, 16 DIMMs per CPU
DIMM type: Registered DDR3L-1600 DIMMs
DIMM size: 32GB
Maximum capacity: 2TB
Standard Integrated Interfaces
Network Four 10 GbE on-board Ethernet copper ports
Network Management One dedicated 10/100/1000 Base-T Ethernet copper management port
Serial Management One RS-232 RJ45 serial port
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
Internal: 1 USB 2.0 Port
PCI Express 11 PCI Express 3.0 Slots
  • 9 slots are x8 PCI-E slots
  • 2 slots are x16 PCI-E slots
Note: Slots 2 is designated for the storage controller HBA.
Video One Rear and One Front HD15 VGA port
Graphics controller VGA 2D graphics controller embedded.
Support remote console at a resolution up to 1600x1200x16bits@60Hz
(1024x678 when viewed remotely via ILOM RKVMS)
Internal Mass Storage
Disks Up to 6 hot-swappable disks

Drive Type
Density
Speed
Form Factor
SAS
1.2TB
10,000 RPM
2.5"

Power Supplies
Dual redundant, hot swappable power supplies
2000W Capacity (From 200 Volts to 240 Volts)
Environment
AC power 100-127 VAC for 2 CPU's
200-240 VAC for 2 or 4 CPU's
50/60 Hz Nominal frequencies
Maximum Input Current 12A @ 100VAC / 12A @ 200VAC
Maximum Power Consumption 1467W
Maximum Heat Output 5005 BTU/hr
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 68° C (-40° F to 154°F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing
Nonoperating: up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3048 m (10,000 ft.), maximum operating temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.)
Acoustic Noise Emissions LwAd (1B= 10dB) at max ambient: 8.9 B (idle and operating room temperature)
LpAm bystander at max ambient: 75 dBA
Regulations
Meets or exceeds the following requirements:
Safety IEC 60950, UL/CSA60950-1, EN60950-1, IEC60950-1 (CB scheme with all country differences), North America (NRTL), European Union (EU), International CB Scheme, 2006/95/EC (73/23/EEC) Low Voltage Directive
EMC FCC CFR 47 Part 15B Class A, EN55022 Class A, CNS-13438 Class A (Taiwan), Title 47, Part 15, Subpart B Class A (Unites States), ICES-003 (A) (Japan), KN 22 RRL Public Notice 2009-9 (Dec 21, 2009)/td>
Immunity EN 55024 (Immunity), EN61000-3-2, EN61000-3-3
Certifications Safety: UL/cUL, UL DEMKO, CCC, CE, BSMI, GOST-R, S-Mark
Regulatory: CE, FCC, EAC, C-Tick, VCCI, BSMI, KCC,ICES-003(A), NMB-3(A), WEE symbol, China RoHS symbol
Dimensions and Weight
Height 129.9 mm (5.1 in.)
Width 436.5 mm (17.2 in.)
Depth 732 mm (28.8 in.)
Weight Maximum: 40 kg (88 lb.)
Rack Mounting
Exalytics In-Memory Machine X4-4 Racks
( Using the Tooless Slide Rail Rackmount Kit PN#371-4791 )
Racks are as follows:
  • Sun Rack 1242
  • Sun Rack 1042

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback