Processor |
Number |
Eight ( per X5-8 Server), Two ( per X6-2L Server) |
Architecture |
Type: Intel Xeon E7-8895 v2 Processor Series (X5-8), Intel Xeon E5-2630 Processor Series (X6-2L) |
CPUs |
Intel 2.60GHz 18-Core Xeon E7-8895 v3, 175W (X5-8), Intel 2.20GHz 10-Core Xeon E5-2630 v4, 85W (X6-2L)
|
X5-8 Capacities |
- Up to Four Oracle Server X5-8 Database Servers
- 6TB Memory (24 DIMM slots per CPU Module x 8 CPU Modules = 192 DIMM slots x 32GB DIMMs)
- Disk Controller HBA with 1GB Cache
- Eight 600GB 10,000 RPM Disk Drives
- 8 x InfiniBand QDR (40Gb/s ports)
- 8 x 10 GbE Ethernet ports based on the Intel 82599 10GbE Controller
- Ten 1GbE Ethernet ports via RJ-45 connectors
- One ILOM port
- Four Redundant Hot-Swappable Power Supplies
|
X6-2L Capacities |
- Up to Fourteen Sun Server X6-2L Storage Servers
- D56 PCI flash cards with 44.8TB (raw) Exadata Smart Flash Cache
- 168 x 3.2TB NVMe High Performance Solid State Drives
- or 168 8TB 7,200 RPM High Capacity Disk Drives
|
Additional Hardware Components |
- Two 36 port QDR (40 Gb/sec) Infiniband Switches
- 42U Rack
- Ethernet switch for administrative connectivity to servers in the Database Machine
- Two Redundant Power Distribution Units (PDU's)
Included Spares Kits Contains:
- One 1.6TB NVMe PCI Flash Card and One 8TB 7200 RPM HC Disk Drive, or
- One 1.6TB NVMe Sold State Drive
|
Optional Software |
X5-8 Database Servers |
Oracle Datadase 11g Release 2 Enterprise Edition and Oracle Database 12c Enterprise Edition |
X6-2L Storage Servers |
Oracle Exadata Storage Server Software (Licenses are transferable) |
Included Software |
X5-8 Database Servers |
Oracle Linux 6 Update 6 with the Unbreakable Enterprise Kernel 2
Zero-loss Zero-copy Datagram Protocol (ZDP) Infiniband protocol used to communicate between the Exadata Storage Servers
and the Oracle Database. |
Environmentals with High Capacity Disk |
Maximum power usage |
16.2 kW (16.6 kVA) |
Typical power usage |
11.4 kW (11.6 kVA) |
Cooling maximum usage |
55,410 BTU/hour (58,457 kj/hour) |
Cooling at typical usage |
38,787 BTU/hour (40,920 kj/hour) |
Airflow at maximum usage |
2,565 CFM |
Airflow at typical usage |
1,796CFM |
Environmentals with High Performance Disk |
Maximum power usage |
16.4 kW (16.7 kVA) |
Typical power usage |
11.5 kW (11.7 kVA) |
Cooling maximum usage |
55,935 BTU/hour (59,012 kj/hour) |
Cooling at typical usage |
39,155 BTU/hour (41,308 kj/hour) |
Airflow at maximum usage |
2,590 CFM |
Airflow at typical usage |
1,813 CFM |
Dimensions and Weight |
Height |
1998 mm (78.66 in.) |
Width |
600 mm (23.62 in.) |
Depth |
1200 mm (47.24 in.) |
Weight |
898.3 kgs (1980.5 lbs.) |