Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Exadata X6-8: Hardware Specifications

Processor
Number Eight ( per X5-8 Server), Two ( per X6-2L Server)
Architecture Type: Intel Xeon E7-8895 v2 Processor Series (X5-8), Intel Xeon E5-2630 Processor Series (X6-2L)
CPUs Intel 2.60GHz 18-Core Xeon E7-8895 v3, 175W (X5-8), Intel 2.20GHz 10-Core Xeon E5-2630 v4, 85W (X6-2L)
X5-8 Capacities
  • Up to Four Oracle Server X5-8 Database Servers
  • 6TB Memory (24 DIMM slots per CPU Module x 8 CPU Modules = 192 DIMM slots x 32GB DIMMs)
  • Disk Controller HBA with 1GB Cache
  • Eight 600GB 10,000 RPM Disk Drives
  • 8 x InfiniBand QDR (40Gb/s ports)
  • 8 x 10 GbE Ethernet ports based on the Intel 82599 10GbE Controller
  • Ten 1GbE Ethernet ports via RJ-45 connectors
  • One ILOM port
  • Four Redundant Hot-Swappable Power Supplies
X6-2L Capacities
  • Up to Fourteen Sun Server X6-2L Storage Servers
  • D56 PCI flash cards with 44.8TB (raw) Exadata Smart Flash Cache
  • 168 x 3.2TB NVMe High Performance Solid State Drives
  • or 168 8TB 7,200 RPM High Capacity Disk Drives
Additional Hardware Components
  • Two 36 port QDR (40 Gb/sec) Infiniband Switches
  • 42U Rack
  • Ethernet switch for administrative connectivity to servers in the Database Machine
  • Two Redundant Power Distribution Units (PDU's)

  • Included Spares Kits Contains:
  • One 1.6TB NVMe PCI Flash Card and One 8TB 7200 RPM HC Disk Drive, or
  • One 1.6TB NVMe Sold State Drive
Optional Software
X5-8 Database Servers Oracle Datadase 11g Release 2 Enterprise Edition and Oracle Database 12c Enterprise Edition
X6-2L Storage Servers Oracle Exadata Storage Server Software (Licenses are transferable)
Included Software
X5-8 Database Servers Oracle Linux 6 Update 6 with the Unbreakable Enterprise Kernel 2

Zero-loss Zero-copy Datagram Protocol (ZDP) Infiniband protocol used to communicate between the Exadata Storage Servers and the Oracle Database.
Environmentals with High Capacity Disk
Maximum power usage 16.2 kW (16.6 kVA)
Typical power usage 11.4 kW (11.6 kVA)
Cooling maximum usage 55,410 BTU/hour (58,457 kj/hour)
Cooling at typical usage 38,787 BTU/hour (40,920 kj/hour)
Airflow at maximum usage 2,565 CFM
Airflow at typical usage 1,796CFM
Environmentals with High Performance Disk
Maximum power usage 16.4 kW (16.7 kVA)
Typical power usage 11.5 kW (11.7 kVA)
Cooling maximum usage 55,935 BTU/hour (59,012 kj/hour)
Cooling at typical usage 39,155 BTU/hour (41,308 kj/hour)
Airflow at maximum usage 2,590 CFM
Airflow at typical usage 1,813 CFM
Dimensions and Weight
Height 1998 mm (78.66 in.)
Width 600 mm (23.62 in.)
Depth 1200 mm (47.24 in.)
Weight 898.3 kgs (1980.5 lbs.)

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.