Processor |
Number |
Eight ( per X4-8 Server), Two ( per X4-2L Server) |
Architecture |
Type: Intel Xeon E7-8895 v2 Processor Series (X4-8), Intel Xeon E5-2630 Processor Series (X4-2L) |
CPUs |
Intel 2.80GHz 15-Core Xeon E7-8895 v2, 155W (X4-8), Intel 2.60GHz 6-Core Xeon E5-2630 (X4-2L)
|
Hardware |
X4-8 Capacities |
- Two Sun Server X4-8 Database Servers
- 2TB Memory (expandable up to 6TB)
- Disk Controller HBA with 512MB battery Backed Write Cache
- Seven 600GB 10,000 RPM Didk Drives
- Eight Infiniband QDR (40Gb/s) Ports
- Eight 10Gb Ethernet ports based on the Intel 82599 10GbE Controller
- Ten 1Gb Ethernet ports
- One ILOM Ethernet ports
- Four Redundant Hot-Swappable Power Supplies
|
X4-2L Capacities |
- Fourteen Sun Server X4-2L Storage Servers
- 168 CPU cores for SQL processing
- D56 PCI flash cards with 44.8TB (raw) Exadata Smart Flash Cache
- 168 x 1.2TB 10,000 RPM High Performance Disk Drives
- or 168 4TB 7,200 RPM High Capacity Disk Drives
|
Additional Hardware Components |
- Two 36 port QDR (40 Gb/sec) Infiniband Switches
- 42U Rack
- Ethernet switch for administrative connectivity to servers in the Database Machine
- Two Redundant Power Distribution Units (PDU's)
Included Spares Kits Contains:
- One 1.2TB 10,000 RPM High Performance Disk Drive
- One 800 GB PCI flash card
|
Optional Software |
X4-8 Database Servers |
Oracle Datadase 11g Release 2 Enterprise Edition and Oracle Database 12c Enterprise Edition |
X4-2L Storage Servers |
Oracle Exadata Storage Server Software (Licenses are transferable) |
Included Software |
X4-8 Database Servers |
Oracle Linux 5 Update 10 with the Unbreakable Enterprise Kernel 2
Zero-loss Zero-copy Datagram Protocol (ZDP) Infiniband protocol used to communicate between the Exadata Storage Servers
and the Oracle Database. |
Environmentals with High Capacity Disk |
Maximum power usage |
14.4 kW (14.7 kVA) |
Typical power usage |
10.1 kW (10.3 kVA) |
Cooling maximum usage |
49,110 BTU/hour (52,000 kj/hour) |
Cooling at typical usage |
34,400 BTU/hour (36,300 kj/hour) |
Airflow at maximum usage |
2,280 CFM |
Airflow at typical usage |
1,600 CFM |
Environmentals with High Performance Disk |
Maximum power usage |
15.0 kW (15.3 kVA) |
Typical power usage |
10.5 kW (10.7 kVA) |
Cooling maximum usage |
51,200 BTU/hour (54,000 kj/hour) |
Cooling at typical usage |
36,400 BTU/hour (38,400 kj/hour) |
Airflow at maximum usage |
2,410 CFM |
Airflow at typical usage |
1,700 CFM |
Dimensions and Weight |
Height |
1998 mm (78.66 in.) |
Width |
600 mm (23.62 in.) |
Depth |
1200 mm (47.24 in.) |
Weight |
867.3 kgs (1912 lbs.) |