Chassis |
- 3U, rackmount
- Front: Display, console, front bezel, fan pack assemblies
- Rear: One NIU slot, two expansion slots for NIU or TCUs, console and alarm ports, three
management ports, USB, redundant power supplies (AC or DC), 480GB disk drive
- Rackmount Options: Four-post cabinet or two-post center mount
Note: The Acme Packet 6350's rear external USB port is not functional.
|
Local Storage |
480GB disk drive
for call detail record storage, log files, and other permanent file
storage |
Transcoding Carrier Unit |
- Up to two modules supported per Acme Packet 6350 chassis
- Supported codecs:
- Wireline - G.711 10, G.711 20, G.722, G.723.1, G.726, G.729A/B, iLBC, Opus, SILK
- Wireless - AMR-NB, AMR-WB, GSM-FR, EVRC, EVRC-B
- T.38 fax interworking
|
Management Interface |
- One RS-232 serial console interface with RJ-45 connector
- One RJ-45 alarm
- One 10/100/1000 Mbps Ethernet interface for RJ-45 management
- Two 10/100/1000 Mbps Ethernet interfaces with RJ-45 for HA
|
Power |
Dual power supplies: Redundant, load-sharing, 1100 W maximum
|
Network Interface Unit (NIU) |
Network Interface Unit |
- Up to two Field-replaceable 2x10 Gbps NIUs
- Two 10 Gbps Ethernet ports with enhanced small form-factor pluggable (SFP+) for short and long reach options:
- SFP+ short reach - 10 GBase-SR 850 nm transceiver for operation in multimode fibre link applications to 300 m
- SFP+ long reach - 10 GBase-LR 1310 nm transceiver for operation in single-mode fibre (SMF) link applications to 10 km
- 32-core processor per interface (two per NIU)
- Optional secure services module (SSM) for hardware acceleration of encryption, compression, hashing, and public key
algorithms for TLS, random number generation, Advanced Encryption Standard (AES), and Triple Data Encryption Standard (3DES)
- Integrated QoS monitoring and measurement
|
|
AC Power |
- Voltage: Autoranging 100V AC to 240V AC wide input with power factor correction
- Frequency: 50/60 Hz
- Current: 100 AC 6A base system, 14A with two transcode carriers (shared between two power supplies)
- Cable: 14 AWG, with three conductors
|
-48 DC Power |
- Voltage: -48V DC (+/− 10%) nominal in North America (maximum range: -40V DC to -60V DC)
- Current: 12A base system, 30A with two transcode carriers (shared between two power supplies)
- Cable: 10 AWG recommended minimum, with at least three conductors rated for at least 60° C (140° F)
|
Temperature |
Operating: +0° C to +40° C (32° F to 104 ° F)
Nonoperating: -20° C to 65° C (-4° F to 149° F) |
Relative Humidity |
Operating: 10% to 85% (non-condensing) |
Altitude |
Operating: 3048m (10000 ft) (max) |
Total Maximum Air Flow |
300 CFM |
Power Dissipation (Base system with 2 x 10GbE NIU) |
Typical: 250W
Maximum: 350W
Additional 150W for second 2 x 10GbE NIU
Additional 275W for each fully populated transcode carrier card
|
|
Height |
13.26 cm (5.22 in) |
Width |
43.43 cm (17.10 in)
(+ mounting ear width: 48.26 cm (19 in) |
Depth |
50.80 cm (20 in) |
Weight (maximum) |
19.27 kg (42.5 lb), fully loaded |
|
Regulatory Markings |
CE, FCC, ICES-003, VCCI, NRTL TUV (US/Canada), KCC, BSMI, EAC, RCM, BIS, ANATEL |
Safety |
EN 60950-1
IEC 60950-1
UL 60950-1
CSA 22.2 No. 60950-1-07 |
EMI |
47CFR15 Subpart B (FCC) Class A
ICES-003 Class A
AS/NZS CISPR22 Class A
CISPR22 Class A
EN300686 for Telecommuniucations Centers and for Other Than Telecommunications Centers
EN 55022 Class A
VCCI Class A limits |
EMC |
EN55024
EN61000-3-2
EN61000-3-3
EN300386:2010 for Telecommuniucations Centers and for Other Than Telecommunications Centers |
Other |
NEBS Level3
ETSI: EN 300019 Class 1.2, 2.2, 3.2
Seismic: GR-63-CORE requirements for earthquake zone 4
1 TR 9
Restriction of Hazardous Substances (RoHS) Directive and Waste Electrical and Electronics Equipment (WEEE) Directive
|
|
The Acme Packet 6350 is contained in a 3U rack-mounted chassis. It can be front or center
mounted in 19" wide racks (up to 32" deep) with options for 23" wide racks. |
Clearance
and Service Access
|
Front |
20 cm (8 in) |
Rear |
20 cm (8 in) |
Leave enough clearance, approximately 20 cm (8 in), in front of the equipment rack
to allow access to the console connector, reset button, graphic display buttons,
and physical interface card slots. |
Leave enough clearance, approximately 20 cm (8 in), in the rear of the equipment rack
to allow for sufficient airflow and for ease in cabling and/or servicing the rear panel. |