Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Acme Packet 6300: Hardware Specifications


Specifications
Chassis
  • 3U, rackmount
  • Front: Display, console, front bezel, fan pack assemblies
  • Rear: One NIU slot, two expansion slots for NIU or TCMs, console and alarm ports, three management ports, redundant power supplies (AC or DC), 600GB disk drive
  • Rackmount Options: Four-post cabinet or two-post center mount
Memory 16GB for configuration files and Acme Packet OS software storage
Local Storage 40GB, 80GB, 400GB, 480GB, 600GB, or 960GB disk drive for call detail record storage, log files, and other permanent file storage
Management Interface
  • One RJ-45 console
  • One RJ-45 alarm
  • One 10/100/1000 Mbps Ethernet interface for management
  • Two 10/100/1000 Mbps Ethernet interfaces for HA
Power Dual power supplies: Redundant, load-sharing, 1100 VA maximum
Network Interface Unit (NIU)
Network Interface Unit
  • Up to two Field-replaceable 2x10 Gbps NIUs
  • Two 10 Gbps Ethernet ports with enhanced small form-factor pluggable (SFP+) for short and long reach options:
    • SFP+ short reach - 10 GBase-SR 850 nm transceiver for operation in multimode fibre link applications to 10 km
    • SFP+ long reach - 10 GBase-LR 1310 nm transceiver for operation in single-mode fibre (SMF) link applications to 10 km
  • 32-core processor per interface (two per NIU)
  • Optional secure services module (SSM) for hardware acceleration of encryption, compression, hashing, and public key algorithms for TLS, random number generation, Advanced Encryption Standard (AES), and Triple Data Encryption Standard (3DES)
  • Integrated QoS monitoring and measurement
Environment
AC Power
  • Voltage: Autoranging 100V AC to 240V AC wide input with power factor correction
  • Frequency: 50/60 Hz
  • Current: 100 AC 6A base system, 14A with two transcode carriers (shared between two power supplies)
  • Cable: 14 AWG, with three conductors
-48 DC Power
  • Voltage: -48V DC (+/− 10%) nominal in North America (maximum range: -40V DC to -60V DC)
  • Current: 12A base system, 30A with two transcode carriers (shared between two power supplies)
  • Cable: 10 AWG recommended minimum, with at least three conductors rated for at least 60° C (140° F)
Temperature Operating: +0° C to +40° C (32° F to 104 ° F)
Nonoperating: -20° C to 65° C (-4° F to 149° F)
Relative Humidity Operating: 10% to 85% (non-condensing)
Altitude Operating: 3048m (10000 ft) (max)
Air Flow 300 CFM
Heat Dissipation Typical: 380W (1300 BTU/hr)
Maximum: 1000W (3400 BTU/hr)
Power Dissipation (Base system with 2 x 10GbE NIU) Typical: 250W
Maximum: 350W
  • Additional 150W for second 2 x 10GbE NIU
  • Additional 275W for each fully populated transcode carrier card
  • Dimensions and Weights
    Height 13.26 cm (5.22 in)
    Width 43.43 cm (17.10 in)
    (+ mounting ear width: 48.26 cm (19 in)
    Depth 50.80 cm (20 in)
    Weight (maximum) 19.27 kg (42.5 lb), fully loaded
    Regulations
    Safety US: UL 60950-1, First Edition, UL 60950-1, 2nd Edition
    Canada: C22.2 No. 60950-1-03, First Edition
    Canada: CSA-C22.2 No. 60950-1-07, Second Edition
    EU: EN 60950-1:2001
    EU: EN and IEC standards for safety and EMI
    EMI US: FCC Part 15 (CFR 47), Class A Limits
    Canada: ICES-003 Issue 4, Class A Limits
    EU: EN 55 022:2006, Class A Limits
    Immunity EU: EN 55 024:1998 + A1:2001 + A2:2003
    EU: EN 300 386 v1.3.3
    EU: EN 300 386 v1.4.2
    NEBS GR-63, GR-1089, SR-3850, Level 3 certified
    EMC US: FCC5 Part 15 (CFR 47), Class A Limits
    Canada: ICES6-003 Issue 4, Class A Limits
    EU: EN55022:2006 + A1:2007, Class A Limits
    Germany: 1 TR 9
    Japan: VCC17, Class A Limits
    Rack Mounting
    The Acme Packet 6300 is contained in a 3U rack-mounted chassis. It can be front or center
    mounted in 19" wide racks (up to 32" deep) with options for 23" wide racks.
    Clearance and Service Access
    Front 20 cm (8 in)
    Rear 10 cm (4 in)
    Leave enough clearance, approximately 20 cm (8 in), in front of the equipment rack
    to allow access to the console connector, reset button, graphic display buttons,
    and physical interface card slots.
    Leave enough clearance, approximately 10 cm (4 in), in the rear of the equipment rack
    to allow for sufficient airflow and for ease in cabling and/or servicing the rear panel.
      Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
     Feedback