Chassis |
- 1U, rackmount
- Front: Display, console, front bezel, fan pack assemblies
- Rear: One NIU/PHY card, console and alarm ports, three management
ports, redundant power supplies (AC or DC)
|
Memory |
16GB for configuration
files and Acme Packet OS software storage |
Management Interface |
- One RJ-45 console
- One RJ-45 alarm
- Three 10/100/1000 Mbps Ethernet interfaces for EMS control,
RADIUS accounting, CLI management, SNMP queries and traps, and
other management functions
|
Local Storage |
40GB, 80GB, 400GB, or 480GB disk drive
for call detail record storage, log files, and other permanent file
storage |
Power |
Dual power supplies: Redundant,
load-sharing, hot-swappable |
Network
Interface Unit (NIU) |
Network Interface Unit |
- One Field-replaceable 2x10 Gbps NIU
- Two 10 Gbps Ethernet ports with enhanced small form-factor pluggable
(SFP+) for short and long reach options:
- SFP+ short reach - 10 GBase-SR 850 nm transceiver for operation
in multimode fibre link applications to 10 km
- SFP+ long reach - 10 GBase-LR 1310 nm transceiver for operation
in single-mode fibre (SMF) link applications to 10 km
- 32-core processor per interface (two per NIU)
- Optional secure services module (SSM) for hardware acceleration
of encryption, compression, hashing, and public key algorithms
for TLS, random number generation, Advanced Encryption Standard
(AES), and Triple Data Encryption Standard (3DES)
- Integrated QoS monitoring and measurement
|
|
AC Power |
- Voltage: Autoranging 100V AC to 240V AC wide input with power
factor correction
- Frequency: 50/60 Hz
- Current: 100V AC 6A base system, 14A with two transcode carriers
(shared between two power supplies)
|
-48 DC Power |
- Voltage: -48V DC (+/− 10%) nominal in North America
(maximum range: -40V DC to -60V DC)
- Current: 12A base system, 30A with two transcode carriers (shared
between two power supplies)
- Cable: 10 AWG recommended minimum, with at least three conductors
rated for at least 60° C (140° F)
|
Temperature |
Operating: 0°
C to 40° C (32° F to 104 ° F)
Nonoperating: -20° C to 65° C (-4° F to 149°
F) |
Relative Humidity |
Operating: 10%
to 85% (non-condensing) |
Altitude |
Operating: 0 -
3048m (10000 ft) (max) |
Air Flow |
100 CFM |
|
Height |
4.37 cm (1.72 in) |
Width |
43.43 cm (17.10 in)
(+ mounting ear width: 48.26 cm (19 in)) |
Depth |
50.80 cm (20 in) (+ mounting
ear width) |
Weight (maximum) |
9.3 kg (20.5 lb), fully
loaded |
|
Safety |
US: UL 60950-1, First Edition, UL 60950-1, 2nd Edition
Canada: C22.2 No. 60950-1-03, First Edition
Canada: CSA3 No. 60950-1-07, Second Edition-C22.2 No. 60950-1-02,
First Edition
EU: EN 60950-1:2001
EU: EN and IEC standards for safety and EMI |
EMI |
US: FCC Part 15 (CFR 47), Class A Limits
Canada: ICES-003 Issue 4, Class A Limits
EU: EN 55 022:2006, Class A Limits |
Immunity |
EU: EN 55 024:1998 + A1:2001 + A2:2003
EU: EN 300 386 v1.3.3
EU: EN 300 386 v1.4.2 |
NEBS |
GR-63, GR-1089, SR-3850, Level 3 certified |
EMC |
US: FCC5 Part 15 (CFR 47), Class A Limits
Canada: ICES6-003 Issue 4, Class A Limits
EU: EN55022:2006 + A1:2007, Class A Limits
Germany: 1 TR 9
Japan: VCC17, Class A Limits |
|
Can be front or center mounted in standard 19" wide
racks (up to 32" deep), with options for 23" wide racks. |
Clearance
and Service Access
|
Leave enough clearance, approximately 20 cm (8 in),
in the rear of the equipment rack
to allow for sufficient airflow and for ease in cabling and/or servicing
the rear panel. |