Sun StorEdge[tm] A5200 Array: Repair Procedures
This section provides the most common repair procedures for the A5200.
The repair procedures are provided in the following manual:
Sun StorEdge A5000 Installation and Service Manual
The table below provides the page numbers that each procedure begins on.
Component
|
Page Number
|
Tips
|
Disk Drive
|
7-3
|
|
Fibre Optic Cable
|
7-8
|
 
|
GBIC
|
7-9
|
-
Some Vixel Short Wave GBICs 370-2303 has been identified as
Long Wave when installed in A5x00 storage array
(FIN I1120-1).
-
Visual identification of -02 and -03 GBICs without
physically removing from system (FIN I0502-1).
-
A small percentage of Vixel GBICs (370-2303-02) are
demonstrating symptoms consistent with marginal signal quality on
the GBaud FC-AL loops. Marginal signal quality can be caused by variations
in component quality for GBICs, backplanes, interface boards, interconnect
assemblies, and FC-AL drives (FCO A0144-3).
|
Interface Board (IB)
|
7-11
|
 
|
Door Panel Assembly
|
7-12
|
 
|
Front Panel Module
|
7-13
|
 
|
Fan Tray
|
7-14
|
 
|
Power Supply
|
7-15
|
 
|
AC Power Filter
|
7-16
|
 
|
Backplane
|
7-17
|
-
The revision level printed on the labels for the 7-slot
Backplane and the 11-slot Backplane for the A5000, A5100, and A5200
array are different than the revision levels that are dynamically
reported by the arrays (FIN I0501-1).
|
Interconnect Assembly
|
7-19
|
-
SMCC Engineering has noted several isolated instances
involving the Enterprise Network Array, where the EMI clip sandwiched
between the underside of the Horizontal Interconnect Board and the
top edge of the Vertical Interconnect Board nearest the Interface
Boards, had shifted just far enough to allow the EMI clip to overlap
and make contact with the soldermask over the Fibre Channel signal
traces (FIN I0373-1).
|