FAB Synopsis Last Modified Date
1231323.1 Relocation of the US HDS Spares Distribution Center for Storage 99xx field returns on or after October 21, 2010. 2012-09-20
1022191.1 Logical Devices in ST9990 may block when the DKU Array Frame is running on only one redundant power supply and a sufficient quantity of DKS2D-K146FC HDDs are installed. 2012-07-31
1020441.1 Must follow Battery Management Procedures to guarantee the integrity of ST9900 products. 2012-09-12
1019622.1 Possible failure of multiple HDDs of certain type within the same Parity Group in ST9990V, ST9985V, ST9990 and ST9985. 2014-06-04
1019433.1 Requirement for SE9900 Series Arrays Microcode level to be at Mandatory General Availability (MGA). 2011-05-12
1017445.1 Essential Battery Management Procedures for Sun StorEdge 99x0 Products. 2012-08-20
1017434.1 Changes to SE99XX activation and notification process for monitored systems. 2010-08-20
1017432.1 Unauthorized modifications to StorEdge 99x0 Service Processor (SVP) - Windows Operating System 2012-08-20
1017362.1 Sun StorEdge 9990 Shared Memory Inconsistency Between Physically Installed and Logically Configured Can Lead to Data Access Disruption or Loss. 2012-08-20
1001324.1 Effective July 13, 2006 - All Case Routing Information For Devices Using the SAMS3/ACCR SSRR HiTrack Applications For Automatic Case Creation And Routing Will Be Handled Via SunRoute. 2010-08-25
1001163.1 New SE9990 DKU backplanes allow FSW-A placement on left side without need for right side FSW PCB. If run in unsupported configurations, disk unit frame will overheat. 2010-09-01
1001062.1 SE9990 SVP - Windows XP SP2 may cause SVP-DKC communication errors. 2012-08-20
1001035.1 Sun StorEdge 99xx Arrays Might Encounter Data Integrity Issues After VMotion Guest Migrations. 2010-08-26
1001020.1 ST99xx Hitachi Hard Drives (DKR2D, DKR2E and DKR2F) reliability improvement. 2010-10-21
1000969.1 Accumulation of memory leak in HDLM for Windows may lead to an application error or system down. 2010-11-12
1000866.1 TagmaStore USP/NSC High Capacity Cache and Shared Memory Installation. 2010-08-31
1000865.1 Devices may become unavailable when attempting USP Non-Stop micro-program exchange on SE9985 or SE9990 systems 2012-08-20
1000857.1 Intermix of HDD from different vendors in parity is supported with pre-requisite Microcode. 2012-08-20
1000853.1 Enabling SE99x0 System Option Mode 186 prevents correct functioning of SCSI-2 Reservations 2010-08-31
1000844.1 SE9990 Parity group addition will fail if the total number of currently installed HDDs + external strorage groups + new HDDs to be installed exceeds 2560. 2010-08-30
1000829.1 Specified SE9990 components now require autodumps to be collected and returned on USB memory devices included with the spare PCBs(printed circuit boards). 2010-09-10
1000814.1 Hitrack Version B.4 And Below Might Report Incorrect Data. 2010-09-10
1000729.1 Incorrectly plugged SE9990 AC box cabling can lead to all devices becoming blocked. 2012-07-31
1000711.1 SE9990 Battery Destage Mode should be set OFF until fixed microcode is released 2010-08-31
1000705.1 Hitrack versions (prior to B.2) for the SE9990 and SE9985 arrays can exit unexpectedly and may not send SIM notifications. 2012-08-20
1000676.1 PFIN - 101976 - International shipments - HDS Microcode CD's and Software Media 2012-07-31
1000485.1 SE9990 Shared Memory or Cache Memory maintenance can cause Microprocessor blockades and lead to a total system outage. 2010-09-10
1000394.1 Hi-Track version 8D Front application terminates unexpectedly when used with early versions of SE9990/USP Microcode. 2010-08-24
1000385.1 Potential for cables to become trapped or mis-connected between DKC/DKU or DKU/DKU frames, during an SE9960, SE9980, or SE9990 unit installation, unit relocation or upgrade. 2012-08-20
1000384.1 Host Group Option 16 cannot be set from Storage Navigator 2010-08-23
1000378.1 Mode 80 disabled will cause "pairresync -restore" to perform a Quick Restore operation, which causes volume maps to swap and can lead to severe performance degradation. 2012-08-20
1000309.1 A microcode bug exists in all V07+1 (50-07-51-00/00 and higher) microcode that in a limited number of configurations can cause all DKA MPs to blockade and recovery may be very disruptive. 2018-03-06
1000222.1 Multiple issues with Graphtrack versions 7.0-7.2 2012-08-20
1000171.1 ECC/LRC pinned data may occur if cache blockades on SE9990/SE9985 2012-08-20