|
Number of disk drives (with spares) |
Up to 120 |
Hot spares (maximum) |
16 |
Individual disk capacities |
73GB (15K RPM)
146GB (10K RPM)
300GB (10K RPM)
|
Total raw capacity per system (73GB drive) |
8.76TB (120 disk drives x 73GB = 8.76TB) |
Total raw capacity per system (146GB drive) |
17.52TB (120 disk drives x 146GB = 17.52TB) |
Total raw capacity per system (300GB drive) |
36TB (120 disk drives x 300GB = 36TB) |
Supported RAID Levels |
RAID 1, RAID 5, RAID 6 |
|
Maximum |
64GB |
Minimum |
4GB |
Increments |
2GB |
|
Maximum |
6GB |
Minimum |
2GB |
|
Maximum of 1 |
|
Up to 16,384 |
|
Front End Director (FED) Ports |
16 FC |
Back End Director (BED) Ports |
8 FC |
1 The "mixed adapter" is new and unique to the Sun StorEdge 9985 system; the mixed adapter
is a combination of FED and BED. This adapter can only be used in slots 1A and 2F. |
|
Number of Slots |
2 |
Designated Slots |
1B and 2E |
2 The "optional slots" are for multi-purpose use. These slots can accommodate FED (CHA),
NAS Blade (CHN), and mainframe adapters such as, FICON and ESCON. |
|
Fibre Channel (fiber-optic cable) |
16-48 2Gb FC Host Ports |
ESCON |
Up to 16 Host Ports |
FICON |
Up to 8 Host Ports |
NAS |
Up to 8 1Gb NAS Ports |
Bandwidth |
Aggregate System
|
12GB/sec |
Maximum System Data
|
8.5GB/sec |
Maximum System Control
|
3.5GB/sec |
|
Temperature |
Operating: 16° to 32° C (60.8° to 89.6° F)
Non-operation: -10° to 43° C (14° to 109.4° F)
Shipping & Storage: -25° to 60° C (-13° to 140° F)
|
Relative Humidity |
Operating: 20% to 80%
Non-operation: 8% to 90%
Shipping & Storage: 5% to 95%
|
Maximum Wet Bulb |
Operating: 26° C (78.8° F)
Non-operation: 27° C (80.6° F)
Shipping & Storage: 29° C (84.2° F)
|
Temperature Deviation Per Hour |
Operating: 10° C (50° F)
Non-operation: 10° C (50° F)
Shipping & Storage: 20° C (68° F)
|
Acoustic Level |
Operating: 65 dB
Non-operation: n/a
Shipping & Storage: n/a
|
|
Height |
Control Array Frame (DKC515I-5/5R): 703 mm (27.7 in.) 4
Array Frame (DKC-F515I-B2R): 522 mm (20.6 in.) |
Width |
Control Array Frame (DKC515I-5/5R): 480 mm (18.9 in.)
Array Frame (DKC-F515I-B2R): 480 mm (18.9 in.) |
Depth |
Control Array Frame (DKC515I-5/5R): 648 mm (25.5 in.)
Array Frame (DKC-F515I-B2R): 648 mm (25.5 in.) |
Weight 5 |
Control Array Frame (DKC515I-5/5R): 82 kg (180.8 lb.)
Array Frame (DKC-F515I-B2R): 66 kg (145.5 lb.) |
3 Allow 596 mm (23.47 in.) in the rear of the unit for service clearance.
4 This dimension includes the thickness of the SVP 43.2 mm (1.7 in.).
5 Refer to the Sun StorEdge 9985 Array documentation for a list of all
component weights within the system.
|