Sun StorEdge 9985 - Full Components List
Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
Hitachi part numbers are listed in the description column, with brackets.
Array Controller
Option #
Manufacturing Part #
Description
Previous Part #
n/a
370-7107 [F]
Serial 8-Port Channel Assembly; WP512-A × 1 and SH343-A × 4, [5524263-A]
n/a
n/a
370-7108 [F]
MF Fibre 4-Port Channel Assembly ; (Short 1-2Gbps) WP515-A × 1 and SH343-A × 4, [5524259-A]
n/a
n/a
370-7109 [F]
MF Fibre 4-Port Channel Assembly; (Long 1-2Gbps) WP515-B × 1 and SH343-A × 4, [5524260-A]
n/a
n/a
370-7112 [F]
NAS 4-Port Channel Assembly; WP517-A × 1 and SH343-A × 1, [5524264-A]
n/a
n/a
370-7114 [F]
Fibre 8-Port Channel Assembly;(Short 1-2Gbps) WP513-A × 1 and SH343-A × 2, [5524257-A]
n/a
n/a
370-7115 [F]
Fibre 16-Port Channel Assembly; (Short 1-2Gbps) WP513-B × 1 and SH343-A × 4, [5524258-A]
n/a
n/a
371-0239 [F]
Printed Circuit Board FSW (SH404-A PK-Assy), (DKC515I-B2R), [5527983-C]
n/a
n/a
371-0246 [F]
Mix Adapter (Fibre 8-port & Disk Adapter 4-port) WP525-Bx1 & SH343-Bx4, (DKC515I-MIX2R), [5527991-C]
n/a
n/a
371-0286 [F]
Serial 8-port Channel Assembly WP512-B x1 & SH343-B x4, (DKC510I-16SR), [5524263-C]
n/a
n/a
371-0287 [F]
MF Fibre 4-port Channel Assembly (Long 1-2Gbps) WP515-D x1 & SH343-B x4, (DKC-F510I-8MLR), [5524260-C]
n/a
n/a
371-0288 [F]
MF Fibre 4-port Channel Assembly (Short 1-2Gbps) WP515-C x1 & SH343-B x4, (DKC-F510I-8MSR), [5524259-C]
n/a
n/a
371-0317 [F]
NAS 4-port Channel Assembly WP517-C x1 & SH343-B x1, (DKC-510I-8NSR), [5524264-C]
n/a
n/a
371-0318 [F]
Fibre 8-port Channel Assembly (Short 1-2Gbps) WP513-C x1 & SH343-B x2, (DKC-F510I-16HSR), [5524257-C]
n/a
n/a
371-0319 [F]
Fibre 16-port Channel Assembly (Short 1-2Gbps) WP513-D x1 & SH343-B x4, (DKC-F510I-32HSR), [5524258-C]
n/a
n/a
371-0320 [F]
Fibre 16-port Channel Assembly (Short 1-4Gbps), [5524268-C]
n/a
n/a
371-1892 [F]
Fibre 16-port Channel Assembly (Short 1-4Gbps), (DKC-F510I-32FS2R), [5524228-C]
n/a
n/a
371-1893 [F]
Fibre 8-Port Channel Assembly; (Short 1-4Gbps) DKC-F510I-16FS2R, [5524222-C]
n/a
n/a
371-2460 [F]
Mix Adapter (Fibre 8-port & Disk Adapter 4-port) WP526-A×1 & SH343-B×4, (DKCF515I-MIX4R), [5527992-C]
n/a
Cables
Option #
Manufacturing Part #
Description
Previous Part #
n/a
371-0247 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 1-A1 (MIX) to RK0-0-B1 (FSW), (DKC515I-UC0R), [5529786-A]
n/a
n/a
371-0248 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 1-A2 (MIX) to RK0-0-A1 (FSW), (DKC515I-UC0R), [5529786-B]
n/a
n/a
371-0249 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 1-A3 (MIX) to RK0-2-A1 (FSW), (DKC515I-UC0R), [5529786-C]
n/a
n/a
371-0250 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 1-A4 (MIX) to RK0-2-B1 (FSW), (DKC515I-UC0R), [5529786-D]
n/a
n/a
371-0251 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 1-A5 (MIX) to RK0-0-A3 (FSW), (DKC515I-UC0R), [5529786-E]
n/a
n/a
371-0252 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 1-A6 (MIX) to RK0-2-A3 (FSW), (DKC515I-UC0R), [5529786-F]
n/a
n/a
371-0253 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 2-F1 (MIX) to RK0-1-B1 (FSW), (DKC515I-UC0R), [5529786-G]
n/a
n/a
371-0254 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 2-F2 (MIX) to RK0-1-A1 (FSW), (DKC515I-UC0R), [5529786-H]
n/a
n/a
371-0255 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 2-F3 (MIX) to RK0-3-A1 (FSW), (DKC515I-UC0R), [5529786-J]
n/a
n/a
371-0256 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 2-F4 (MIX) to RK0-3-B1 (FSW), (DKC515I-UC0R), [5529786-K]
n/a
n/a
371-0257 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 2-F5 (MIX) to RK0-1-A3 (FSW), (DKC515I-UC0R), [5529786-L]
n/a
n/a
371-0258 [F]
Cable Device Interface (connects DKC and DKU-UC0R) 2-F6 (MIX) to RK0-3-A3 (FSW), (DKC515I-UC0R), [5529786-M]
n/a
n/a
371-0259 [F]
Cable (DKC to DKU-UC1R) RK0-0-B2 (FSW) to RK1-0-B1 (FSW) AND/ RK2-0-B2 (FSW) to RK3-0-B1 (FSW), (DKC515I-UC1R), [5529787-A]
n/a
n/a
371-0260 [F]
Cable (DKC to DKU-UC1R) RK0-0-A2 (FSW) to RK1-0-A1 (FSW) AND/ RK2-0-A2 (FSW) to RK3-0-A1 (FSW), (DKC515I-UC1R), [5529787-B]
n/a
n/a
371-0261 [F]
Cable (DKC to DKU-UC1R) RK0-2-A2 (FSW) to RK1-2-A1 (FSW) AND/ RK2-2-A2 (FSW) to RK3-2-A1 (FSW), (DKC515I-UC1R), [5529787-C]
n/a
n/a
371-0262 [F]
Cable (DKC to DKU-UC1R) RK0-2-B2 (FSW) to RK1-2-B1 (FSW) AND/ RK2-2-B2 (FSW) to RK3-2-B1 (FSW), (DKC515I-UC1R), [5529787-D]
n/a
n/a
371-0263 [F]
Cable (DKC to DKU-UC1R) RK0-0-A4 (FSW) to RK1-0-A3 (FSW) AND/ RK2-0-A4 (FSW) to RK3-0-A3 (FSW), (DKC515I-UC1R), [5529787-E]
n/a
n/a
371-0264 [F]
Cable (DKC to DKU-UC1R) RK0-2-A4 (FSW) to RK1-2-A3 (FSW) AND/ RK2-2-A4 (FSW) to RK3-2-A3 (FSW), (DKC515I-UC1R), [5529787-F]
n/a
n/a
371-0265 [F]
Cable (DKC to DKU-UC1R) RK0-1-B2 (FSW) to RK1-1-B1 (FSW) AND/ RK2-1-B2 (FSW) to RK3-1-B1 (FSW), (DKC515I-UC1R), [5529787-G]
n/a
n/a
371-0266 [F]
Cable (DKC to DKU-UC1R) RK0-1-A2 (FSW) to RK1-1-A1 (FSW) AND/ RK2-1-A2 (FSW) to RK3-1-A1 (FSW), (DKC515I-UC1R), [5529787-H]
n/a
n/a
371-0267 [F]
Cable (DKC to DKU-UC1R) RK0-3-A2 (FSW) to RK1-3-A1 (FSW) AND/ RK2-3-A2 (FSW) to RK3-3-A1 (FSW), (DKC515I-UC1R), [5529787-J]
n/a
n/a
371-0268 [F]
Cable (DKC to DKU-UC1R) RK0-3-B2 (FSW) to RK1-3-B1 (FSW) AND/ RK2-3-B2 (FSW) to RK3-3-B1 (FSW), (DKC515I-UC1R), [5529787-K]
n/a
n/a
371-0269 [F]
Cable (DKC to DKU-UC1R) RK0-1-A4 (FSW) to RK1-1-A3 (FSW) AND/ RK2-1-A4 (FSW) to RK3-1-A3 (FSW), (DKC515I-UC1R), [5529787-L]
n/a
n/a
371-0270 [F]
Cable (DKC to DKU-UC1R) RK0-3-A4 (FSW) to RK1-3-A3 (FSW) AND/ RK2-3-A4 (FSW) to RK3-3-A3 (FSW), (DKC515I-UC1R), [5529787-M]
n/a
n/a
371-0271 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-0-B2 (FSW) to RK2-0-B1 (FSW), (DKC515I-EXC0R), [5529790-A]
n/a
n/a
371-0272 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-0-A2 (FSW) to RK2-0-A1 (FSW), (DKC515I-EXC0R), [5529790-B]
n/a
n/a
371-0273 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-2-A2 (FSW) to RK2-2-A1 (FSW), (DKC515I-EXC0R), [5529790-C]
n/a
n/a
371-0274 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-2-B2 (FSW) to RK2-2-B1 (FSW), (DKC515I-EXC0R), [5529790-D]
n/a
n/a
371-0275 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-0-A4 (FSW) to RK2-0-A3 (FSW), (DKC515I-EXC0R), [5529790-E]
n/a
n/a
371-0276 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-2-A4 (FSW) to RK2-2-A3 (FSW), (DKC515I-EXC0R), [5529790-F]
n/a
n/a
371-0277 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-1-B2 (FSW) to RK2-1-B1 (FSW), (DKC515I-EXC0R), [5529790-G]
n/a
n/a
371-0278 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-1-A2 (FSW) to RK2-1-A1 (FSW), (DKC515I-EXC0R), [5529790-H]
n/a
n/a
371-0279 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-3-A2 (FSW) to RK2-3-A1 (FSW), (DKC515I-EXC0R), [5529790-J]
n/a
n/a
371-0280 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-3-B2 (FSW) to RK2-3-B1 (FSW), (DKC515I-EXC0R), [5529790-K]
n/a
n/a
371-0281 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-1-A4 (FSW) to RK2-1-A3 (FSW), (DKC515I-EXC0R), [5529790-L]
n/a
n/a
371-0282 [F]
Cable Device Interface (connects DKC and DKU-EXC0R) RK1-3-A4 (FSW) to RK2-3-A3 (FSW), (DKC515I-EXC0R), [5529790-M]
n/a
Communication
Option #
Manufacturing Part #
Description
Previous Part #
n/a
371-0283 [F]
Modem Card (ME5614CG3), [5524212-C]
n/a
Disks
Option #
Manufacturing Part #
Description
Previous Part #
TJ9DKUF515I-146K1R
371-1532
146GB FC Disk Drive/15k RPM
n/a
TJ9DKUF515I-146KSR
371-1531
146GB FC Disk Drive/15kmin
n/a
TJ9DKUF515I-300K1R
371-3713
1 HDD Spare Canister (300GB/15K RPM) (Multi Vendor)[5524276-E]
n/a
TJ9DKUF515I-300KSR
371-3712
1 HDD Spare Canister (300GB/15K RPM) (Multi Vendor)[5524276-D]
n/a
TV9DKUF515I-400J1R
371-4215
1 HDD Spare Canister (400GB - 10K RPM FC)
n/a
TV9DKUF515I-400JSR
[S]
371-4211
1 HDD Canister (400GB - 10K RPM FC)
n/a
n/a
370-7127 [F]
72GB Disk Drive/15kmin-1; (DKS2C-K72FC), [5524271-A]
n/a
n/a
370-7128 [F]
146GB Disk Drive/10kmin-1; (DKR2A-J146FC), [5524269-A]
n/a
n/a
371-0323 [F]
72GB Disk Drive/15kmin-1 (DKS2D-K72FC), [5524271-D]
n/a
n/a
371-0324 [F]
146GB Disk Drive/10kmin-1 (DKR2D-J146FC/DKR2F-J146FC), (DKU-505I-146JSR), [5524269-D]
n/a
n/a
371-0325 [F]
146GB Disk Drive/15kmin-1;(DKS2D-K146FC), [5524272-D]
n/a
n/a
371-0326 [F]
300GB Disk Drive/10kmin-1 (DKS2D-J300FC), [5524270-D]
n/a
n/a
371-0341 [F]
146GB Disk Drive/15kmin-1; HDU500-146K1FC (DKS2D-K146FC), [5524272-A]
n/a
n/a
371-3638 [F]
300GB Disk drive/15kmin-1 (DKS2E-K300FC/DKS2F-K300FC), [5524276-D|E]
n/a
n/a
371-4207 [F]
400GB Disk drive/10kmin-1 (DKS2E-J400FC), [5524277-E]
n/a
n/a
371-4489 [F]
146GB Disk Drive/10kmin-1 (DKR2E-J146FC/DKR2F-J146FC),[5524269-E]
371-0324 [F]
n/a
371-4490 [F]
300GB Disk Drive/10kmin-1 (DKS2E-J300FC),[5524270-E]
371-0326 [F]
n/a
371-4491 [F]
72GB Disk Drive/15kmin-1 (DKS2E-K72FC),[5524271-E]
371-4495 [F]
+
371-0323 [F]
n/a
371-4492 [F]
146GB Disk Drive/15kmin-1 (DKS2E-K146FC),[5524272-E]
371-0325 [F]
n/a
371-4493 [F]
146GB Disk Drive/10kmin-1 (DKS2D-J146FC),[5524269-F]
371-4489 [F]
+
371-0324 [F]
n/a
371-4494 [F]
300GB Disk Drive/10kmin-1 (DKR2F-J300FC),[5524270-F]
371-4490 [F]
+
371-0326 [F]
n/a
371-4495 [F]
72GB Disk Drive/15kmin-1 (DKS2F-K72FC),[5524271-F]
371-0323 [F]
n/a
371-4496 [F]
146GB Disk Drive/15kmin-1 (DKR2F-K146FC/DKR2G-K146FC),[5524272-F]
371-4492 [F]
+
371-0325 [F]
n/a
371-0691 [F]
[S]
146GB Disk Drive/15kmin-1; HDU500-146K1FC (DKS2D-K146FC), [5524272-D]
n/a
Ethernet
Option #
Manufacturing Part #
Description
Previous Part #
TJ9DKCF515I-8ISR
371-2279
iSCSI 8-port Channel Adapter (1.25Gbps Gigabit Ether Ports, Short-wave)
n/a
Fan
Option #
Manufacturing Part #
Description
Previous Part #
n/a
371-0241 [F]
Fan Assembly for DKC with TH Assembly, (DKC515I-5/5R), [5527963-C]
n/a
n/a
371-0242 [F]
Fan Assembly for DKC, (DKC515I-5/5R), [5527964-C]
n/a
Fibre Channel
Option #
Manufacturing Part #
Description
Previous Part #
TJ9DKCF515I-16MFLR
371-2520
4Gb/sec FICON 16 Port Long Wavelength (single mode) Channel Adapter
n/a
TJ9DKCF515I-16MFSR
371-2519
4Gb/sec FICON 16 Port Short Wavelength (multi-mode) Channel Adapter
n/a
TJ9DKCF510I-1FLR
[S]
371-2068
1-4Gbps Fibre Channel Transceiver Long Wave SFP
n/a
TJ9DKCF510I-1FSR
[S]
371-2067
1-4Gbps Fibre Channel Transceiver Short Wave SFP
n/a
TJ9DKCF515I-MIX4R
[S]
371-2521
4Gb/sec Mixed Fibre Channel Adapter Board, Short Wave SFP
n/a
n/a
370-7116
[F]
2Gb/Sec Long Wave SFP Transceiver, [5524230-A]
n/a
n/a
370-7117
[F]
2Gb/Sec Short Wave SFP Transceiver, [5524229-A]
n/a
n/a
371-0321 [F]
Fibre SFP Transceiver for Long Wavelength, (DKC-F510I-1HLR), [5524230-C]
n/a
n/a
371-0322 [F]
Fibre SFP Transceiver for Short Wavelength, (DKC-F510I-1HSR), [5524229-C]
n/a
n/a
371-1890 [F]
1-4Gbps Fibre Channel Transceiver Short Wave SFP, (DKC-F510I-1FSR), [5524231-C]
n/a
n/a
371-1891 [F]
1-4Gbps Fibre Channel Transceiver Long Wave SFP, (DKC-F510I-1FLR), [5524234-C]
n/a
Memory
Option #
Manufacturing Part #
Description
Previous Part #
DKC-F510I-C8GR
8GB Cache Memory Module Option
371-1557 [F]
PCB CM 2GB DIMM (SH342-D PK-ASSY) [5524242-C]
n/a
TJ9DKCF515I-C8GR 4
[S]
8GB Cache Memory Module Option
371-1557 [F]
PCB CM 2GB DIMM (SH342-D PK-ASSY) [5524242-C]
n/a
TJ9DKCF515I-S2GR 5
[S]
2GB Shared Memory Module Option
371-1558 [F]
PCB SM DIMM (SH341-D PK-ASSY) [5524237-C]
n/a
n/a
370-7104 [F]
Printed Circuit Board SM DIMM; SH341-A, [5524235-A] PK-Assy
n/a
n/a
370-7105 [F]
Printed Circuit Board CM 1GB DIMM; SH342-A, [5524236-A] PK-Assy
n/a
n/a
371-0245 [F]
Printed Circuit Board BASE (WP535-A PK-Assy), (DKC515I-5/5R), [5527989-C]
n/a
n/a
371-0284 [F]
Printed Circuit Board SM DIMM (SH341-C PK-Assy), (DKC510I-S1GR), [5524235-C]
n/a
n/a
371-0285 [F]
Printed Circuit Board CM 1GB DIMM (SH342-C PK-Assy), (DKC510I-C4GR), [5524236-C]
n/a
4 Maximum number of installable options is:
* 8 sets (Cache capacity: 32GB) when the DKC-F510I-CX1GR is not
installed, or
* 8 sets (Cache capacity: 64GB) when the DKC-F510I-CX1GR is installed.
5 Required number of shared memory is determined based on the cache capacity of the subsystem,
disk capacity (number of LDEVs), and program products to be installed.
Power
Option #
Manufacturing Part #
Description
Previous Part #
n/a
371-0236 [F]
Battery Box for DKC515I, (DKC515I-LGABR), [5527959-C]
n/a
n/a
371-0237 [F]
AC/DC Box - 960-C, (DKC515I-5/5R), [5527960-C]
n/a
n/a
371-0238 [F]
AC/DC Box - 961-C, (DKC515I-B2R), [5527961-C]
n/a
Rack
Option #
Manufacturing Part #
Description
Previous Part #
TJ97846443R
[S]
371-1835
Sun StorEdge 19 inch Global Rack (US and the Americas)
n/a
TJ97846444R
[S]
371-1836
Sun StorEdge 19 inch Global Rack (APAC)
n/a
TJ97846445R
[S]
371-1837
Sun StorEdge 19 inch Global Rack (EMEA)
n/a
Switch/Hub
Option #
Manufacturing Part #
Description
Previous Part #
TJ9DKCF510I-16FS2R
[S]
371-2071
FC 16-Port Front End Director (Short Wavelength 1-4Gbps)
n/a
System Service Processor
Option #
Manufacturing Part #
Description
Previous Part #
n/a
371-0240 [F]
SVP for DKC515I, (DKC515I-5/5R), [5527951-C]
n/a
n/a
371-0244 [F]
Printed Circuit Board SSVP (SH407-A PK-Assy), (DKC515I-5/5R), [5527978-C]
n/a
Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part