Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun ZFS Storage 7420: Hardware Specifications

Processor
Number 2 or 4 6-Core, 8-Core or 10-Core
Architecture Sun Fire X4470 supports the: Intel Xeon 7500 Processor Series
Sun Fire X4470 M2 supports the: Intel Xeon E7 Processor Series
CPUs Sun Fire X4470 supported CPU Modules include:
  • Intel 1.86GHz 6-Core Xeon E7530, 105W
  • Intel 2.00GHz 8-Core Xeon X7550, 130W
  • Sun Fire X4470 M2 supported CPU Modules include:
  • Intel 2.00GHz 8-Core Xeon E7-4820, 105W
  • Intel 2.40GHz 10-Core Xeon E7-4870, 130W
  • Cache memory Sun Fire X4470 Cache:
    256KB unified (data and instruction) Level 2 cache
    12MB, 18MB or 24MB shared inclusive Level 3 cache
    Sun Fire X4470 M2 Cache:
    256KB unified (data and instruction) Level 2 cache
    18MB or 30MB shared inclusive Level 3 cache
    Main Memory
    Capacities DIMM slots: 64 DIMM slots, 16 DIMMs per CPU
    DIMM type: Registered DDR3-1333/PC3-10600 ECC DIMMs
    Registered DDR3-1066/PC3-8500 ECC DIMMs
    DIMM size: 4GB, 8GB or 16GB
    Maximum capacity Sun Fire X4470: 512GB
    Maximum capacity Sun Fire X4470 M2: 1TB
    Standard Integrated Interfaces
    Network Four Integrated 10/100/1000 Base-T Gigabit Ethernet
    Network Management One 10/100 Base-T Ethernet management port
    Serial Management One TIA/EIA-232-F asynchronous RJ45 serial port
    USB Front: 2 USB 2.0 Ports
    Rear: 2 USB 2.0 Ports
    Internal: 1 USB 2.0 Port
    PCI Express 10 PCI Express 2.0 Slots
    • 2 slots (3 and 5) are either x8 or x16 electrical interface (x16 connector)
    • 6 slots are x8 PCI-E slots
    • 2 slots are x4 PCI-E slots
    Note: Slots 3 and 5 operate as x16 interfaces only when an x16 capable card is
    installed and the adjacent slot (4 or 6) is unpopulated.
    Video One Rear and One Front HD15 VGA port
    Internal Mass Storage
    Disks Up to 6 hot-swappable disks in the Sun Fire X4470 or X4470 M2 & 24 hot-swappable disks in the Sun Disk Shelf 24x3.5" SAS-2, Oracle Storage DE2-24C and Oracle Storage DE2-24P

    Part Number
    Part Description
    Form Factor
    Supported In
    Disks - ZFS Storage 7420 (X4470 Server Head - Marlin bracket)
    542-0371 [C]
    500GB - 7200 RPM SATA Disk Assembly
    2.5"
    ZFS Storage 7420 (X4470 Server Head)
    7042768 [C]
    500GB - 10000 RPM SATA Disk Assembly
    2.5"
    ZFS Storage 7420 (X4470 Server Head)
    542-0330 [C]
    512GB Solid State SATA-2 Drive Assembly
    2.5"
    ZFS Storage 7420 (X4470 Server Head)
    7010845 [C]
    512GB Solid State SATA-2 Drive Assembly
    2.5"
    ZFS Storage 7420 (X4470 Server Head)
    Disks - ZFS Storage 7420 + (X4470 M2 Server Head - Marlin bracket)
    542-0371 [C]
    500GB - 7200 RPM SATA Disk Assembly
    2.5"
    ZFS Storage 7420 (X4470 M2 Server Head)
    542-0330 [C]
    512GB Solid State SATA-2 Drive Assembly
    2.5"
    ZFS Storage 7420 (X4470 M2 Server Head)
    7010845 [C]
    512GB Solid State SATA-2 Drive Assembly
    2.5"
    ZFS Storage 7420 (X4470 M2 Server Head)
    Disks - ZFS Storage 7420 M2 (X4470 M2 Server Head - Marlin bracket)
    7066874 [C]
    900GB - 10000 RPM SAS Disk Assembly
    2.5"
    ZFS Storage 7420 (X4470 M2 Server Head)
    7046052 [C]
    1.6TB SAS Solid State Drive Assembly
    2.5"
    ZFS Storage 7420 (X4470 M2 Server Head)
    7097377 [C]
    1.6TB SAS Solid State Drive Assembly
    2.5"
    ZFS Storage 7420 (X4470 M2 Server Head)
    Disks - Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980 - Stingray bracket)
    7309527 [C]
    18GB SAS Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    7015704 [C]
    18GB SAS Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    7048983 [C]
    73GB SAS-2 Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    7048042 [C]
    73GB SAS-2 Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    7011094 [C]
    73GB SAS Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    7309938 [C]
    200B SAS-3 Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    542-0191 [C]
    300GB - 15000 RPM SAS Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    542-0179 [C]
    600GB - 15000 RPM SAS Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    542-0274 [C]
    2TB - 7200 RPM SAS Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    542-0340 [C]
    1TB - 7200 RPM SAS Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#540-7980)
    Disks - Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264 - Stingray bracket)
    7011094 [C]
    73GB SAS Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    7048042 [C]
    73GB SAS-2 Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    7048983 [C]
    73GB SAS-2 Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    7309938 [C]
    200B SAS-3 Solid State Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    542-0191 [C]
    300GB - 15000 RPM SAS Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    7047155 [C]
    300GB - 15000 RPM SAS Disk Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    542-0179 [C]
    600GB - 15000 RPM SAS Drive Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    7047035 [C]
    600GB - 15000 RPM SAS Disk Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    542-0340 [C]
    1TB - 7200 RPM SAS Disk Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    542-0274 [C]
    2TB - 7200 RPM SAS Disk Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    7042964 [C]
    2TB - 7200 RPM SAS Disk Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    7010135 [C]
    3TB - 7200 RPM SAS Disk Assembly
    3.5"
    Disk Shelf 24x3.5' SAS-2 (Chassis PN#7041264)
    Disks - Storage DE2-24P - Evo bracket
    7044379 [C]
    73GB SAS Solid State Drive Assembly
    2.5"
    DE2-24P
    7094126 [C]
    200GB - Solid State SAS Disk Assembly
    2.5"
    DE2-24P
    7044283 [C]
    300GB - 10000 RPM SAS Disk Drive Assembly
    2.5"
    DE2-24P
    7093029 [C]
    600GB - 10000 RPM SAS Disk Drive Assembly
    2.5"
    DE2-24P
    7044376 [C]
    900GB - 10000 RPM SAS Disk Drive Assembly
    2.5"
    DE2-24P
    7093044 [C]
    1.2TB - 10000 RPM SAS Disk Drive Assembly
    2.5"
    DE2-24P
    Disks - Storage DE2-24C - Heron bracket
    7044396 [C]
    73GB SAS Solid State Drive Assembly
    3.5"
    DE2-24C
    7094120 [C]
    200GB - Solid State SAS Disk Assembly
    3.5"
    DE2-24C
    7044391 [C]
    3TB - 7200 RPM SAS Disk Drive Assembly
    3.5"
    DE2-24C
    7066831 [C]
    4TB - 7200 RPM SAS Disk Drive Assembly
    3.5"
    DE2-24C
    7301592 [C]
    8TB - 7200 RPM SAS Disk Drive Assembly
    3.5"
    DE2-24C

    Power Supplies
    Dual redundant, hot swappable power supplies
    2000W Capacity (From 200 Volts to 240 Volts)
    Environment
    Power Consumption Online power calculator
    AC power 100-127 VAC/200-240 VAC (50-60Hz)
    Maximum Input Current 12A @ 100VAC / 12A @ 200VAC
    Maximum Power Consumption 1800W
    Maximum Heat Output 6143 BTU/hr
    Temperature Single, non-rack system:
    Operating: 5° C to 35° C (41° F to 95° F)
    Nonoperating: -40° C to 68° C (-40° F to 154° F)
    Humidity Single, non-rack system:
    Operating: 10% to 90% relative humidity noncondensing
    Nonoperating: up to 93% relative humidity noncondensing
    Altitude Single, non-rack system:
    Operating: Up to 3048 m (10,000 ft.), maximum operating temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
    Nonoperating: Up to 12,000 m (39,370 ft.)
    Acoustic Noise Emissions LwAd (1B= 10dB) at max ambient: 8.9 B (idle and operating room temperature)
    LpAm bystander at max ambient: 75 dBA
    Regulations
    Meets or exceeds the following requirements:
    Safety IEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences
    RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN300-386, EN 61000-3-2, EN 61000-3-3
    Immunity EN 55024 ,EN 300 386
    Certifications Safety: UL/cUL, UL DEMKO, CCC, CE, BSMI, GOST-R, S-Mark
    EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
    Other: Labeled per WEEE (Waste Electrical and Electronic Equipment) Directive (2002/96/EC) and RoHS Directive (2002/95/EC)
    Dimensions and Weight (Sun Fire X4470)
    Height 129.85 mm (5.1 in.)
    Width 436.5 mm (17.2 in.)
    Depth 732 mm (28.8 in.)
    Weight Maximum: 38.5 kg (85 lb.)
    Minimum: 29.5 kg (65 lb.)
    Rack Mounting
    Sun ZFS Storage 7420 Racks Racks are as follows:
    • Sun Rack II 1242
    • Sun Rack II 1042

      Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
     Feedback