Replicated from Sun Bug ID 15556515 [SUNBT6830817]:

  1. Take off 3-pin connector (black, red and yellow cables) x2 from F2 and F3 on the system board of Netra 240.
  2. Release the fixed CPU Blower.
  3. Connect 3-pin connectors (white cable) x2 to F2 and F3 respectively on the system board of Netra 240.
  4. Connect 4-pin connectors (black and red cables) to 4-pin connectors that come from the Power Distribution Board.
  5. Affix the CPU Blower.